Source:http://linkedlifedata.com/resource/pubmed/id/16356460
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2005-12-30
|
pubmed:abstractText |
The retention behavior of the unmodified phosphodiester oligonucleotide sequence isomers was investigated on two different anion exchange columns: Biospher GMB 1000Q (based on DEAE-modified glycidyl methacrylate) and PolyWAX LP (based on silica with a crosslinked coating of linear polyethyleneimine). There was a notable difference in retention of oligonucleotides of the same composition but differing in the position of a single base. The most pronounced difference was observed between the oligonucleotides with the variable base in the end and in the center of the sequence. The use of either acetonitrile or 2-propanol as a mobile phase organic modifier did not markedly affect the retention time patterns. Prediction of the retention times of oligonucleotides must take into account the base position as well as identity. This is the first report of such a "same composition different sequence" effect, described for the short peptides, for synthetic oligonucleotides.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/2-Propanol,
http://linkedlifedata.com/resource/pubmed/chemical/Acetonitriles,
http://linkedlifedata.com/resource/pubmed/chemical/Anion Exchange Resins,
http://linkedlifedata.com/resource/pubmed/chemical/Oligonucleotides,
http://linkedlifedata.com/resource/pubmed/chemical/acetonitrile
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0003-2697
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
15
|
pubmed:volume |
348
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
300-6
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:16356460-2-Propanol,
pubmed-meshheading:16356460-Acetonitriles,
pubmed-meshheading:16356460-Anion Exchange Resins,
pubmed-meshheading:16356460-Base Sequence,
pubmed-meshheading:16356460-Chromatography, High Pressure Liquid,
pubmed-meshheading:16356460-Chromatography, Ion Exchange,
pubmed-meshheading:16356460-Isomerism,
pubmed-meshheading:16356460-Oligonucleotides
|
pubmed:year |
2006
|
pubmed:articleTitle |
Unusual chromatographic behavior of oligonucleotide sequence isomers on two different anion exchange HPLC columns.
|
pubmed:affiliation |
Generi Biotech, Machkova 587, 500 11 Hradec Králové, Czech Republic. martin.buncek@generi-biotech.com
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, Non-U.S. Gov't
|