pubmed:abstractText |
This study compared simultaneous intravesical pressure readings obtained with catheter-mounted microtip transducers and external water pressure transducer catheters during filling cystometry. Women undergoing multichannel urodynamic testing were randomly assigned to one of three groups: two microtip catheters, two external water pressure transducer catheters, or one of each type. Intravesical pressure was measured simultaneously for each transducer combination in each subject for minimal and maximal Valsalva effort and minimal, moderate, and maximal cough effort at two sequential bladder volumes (150 and 300 ml). Paired t tests were used to compare the means of the intravesical pressure obtained by the two types of catheters. The largest mean differences were observed when comparing microtip and water pressure transducers. Correlations of maximum pressure were consistently high between two microtip transducers and two water pressure transducers but lower for the microtip-water combination. Excellent reproducibility was demonstrated with transducers of similar types for intravesical pressures recorded during Valsalva and cough in women without prolapse. However, considerable variability was seen in pressures recorded by different transducers, particularly dependent on the water catheter manufacturer, indicating that intravesical pressure recordings from microtip and water-based systems are not interchangeable.
|
pubmed:grant |
http://linkedlifedata.com/resource/pubmed/grant/U01 HD41249,
http://linkedlifedata.com/resource/pubmed/grant/U10 HD41248,
http://linkedlifedata.com/resource/pubmed/grant/U10 HD41250,
http://linkedlifedata.com/resource/pubmed/grant/U10 HD41261,
http://linkedlifedata.com/resource/pubmed/grant/U10 HD41263,
http://linkedlifedata.com/resource/pubmed/grant/U10 HD41267,
http://linkedlifedata.com/resource/pubmed/grant/U10 HD41268,
http://linkedlifedata.com/resource/pubmed/grant/U10 HD41269
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:author |
pubmed-author:BrownMorton BMB,
pubmed-author:BrubakerLindaL,
pubmed-author:CundiffGeoffrey WGW,
pubmed-author:HundleyAndrew FAF,
pubmed-author:KrederKarlK,
pubmed-author:LotzePeterP,
pubmed-author:RichterHolly EHE,
pubmed-author:ViscoAnthony GAG,
pubmed-author:WeberAnne MAM,
pubmed-author:ZyczynskiHalinaH
|
pubmed:volume |
17
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
400-6
|
pubmed:dateRevised |
2011-8-18
|
pubmed:meshHeading |
pubmed-meshheading:16284710-Adult,
pubmed-meshheading:16284710-Aged,
pubmed-meshheading:16284710-Aged, 80 and over,
pubmed-meshheading:16284710-Equipment Design,
pubmed-meshheading:16284710-Female,
pubmed-meshheading:16284710-Humans,
pubmed-meshheading:16284710-Manometry,
pubmed-meshheading:16284710-Middle Aged,
pubmed-meshheading:16284710-Reproducibility of Results,
pubmed-meshheading:16284710-Transducers, Pressure,
pubmed-meshheading:16284710-Urinary Bladder,
pubmed-meshheading:16284710-Urinary Incontinence,
pubmed-meshheading:16284710-Urodynamics
|
pubmed:year |
2006
|
pubmed:articleTitle |
A multicentered comparison of measurements obtained with microtip and external water pressure transducers.
|
pubmed:affiliation |
Division of Female Pelvic Medicine and Reconstructive Pelvic Surgery, University of North Carolina at Chapel Hill, Chapel Hill, NC, USA.
|
pubmed:publicationType |
Journal Article,
Randomized Controlled Trial,
Multicenter Study,
Research Support, N.I.H., Extramural
|