Source:http://linkedlifedata.com/resource/pubmed/id/16240109
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
2006-2-14
|
pubmed:abstractText |
A rapid (5.5 min) one-step whole blood C-reactive protein (CRP) magnetic permeability immunoassay utilizing monoclonal antibody conjugated dextran iron oxide nanoparticles (70 nm) as superparamagnetic labels and mixed fractions (1:1 ratio of 15-40 and 60 microm) of polyclonal anti-CRP conjugated silica microparticles for enhanced sedimentation is described. In this one-step assay procedure, a whole blood sample (4 microl) is applied to an assay glass vial, containing both antibody conjugates, and mixed for 30 s. The target analyte, CRP, forms a sandwich complex between the conjugated nanoparticles and microparticles, and, subsequently, the complex sediments under normal gravitation within 5 min to the bottom of the vial. The magnetic permeability increase of the sediment due to the presence of the complexed superparamagnetic nanoparticles is determined using an inductance-based transducer. Assayed patient whole blood samples were compared with the Abbott Diagnostics Architect reference method. A strong linear correlation was observed for the CRP concentration range 0-260 mg/l in whole blood (y=1.001x+0.42, R2=0.982, n=50). The CRP assay presented showed a limit of detection of 3 mg/l and a total imprecision (coefficient of variation) of 10.5%. On the basis of our observations, we propose a rapid, one-step, CRP assay for near-patient testing.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Feb
|
pubmed:issn |
1618-2642
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
384
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
651-7
|
pubmed:meshHeading |
pubmed-meshheading:16240109-Antibodies, Monoclonal,
pubmed-meshheading:16240109-C-Reactive Protein,
pubmed-meshheading:16240109-Calibration,
pubmed-meshheading:16240109-Humans,
pubmed-meshheading:16240109-Immunoassay,
pubmed-meshheading:16240109-Magnetics,
pubmed-meshheading:16240109-Nanoparticles,
pubmed-meshheading:16240109-Particle Size,
pubmed-meshheading:16240109-Reproducibility of Results,
pubmed-meshheading:16240109-Sensitivity and Specificity,
pubmed-meshheading:16240109-Silicon Dioxide,
pubmed-meshheading:16240109-Surface Properties
|
pubmed:year |
2006
|
pubmed:articleTitle |
Rapid one-step whole blood C-reactive protein magnetic permeability immunoassay with monoclonal antibody conjugated nanoparticles as superparamagnetic labels and enhanced sedimentation.
|
pubmed:affiliation |
Department of Pure and Applied Biochemistry, Lund University, P.O. Box 124, 221 00, Lund, Sweden.
|
pubmed:publicationType |
Journal Article
|