pubmed:abstractText |
Co-registration accuracy in combined whole-body (WB) PET/CT imaging is impaired by respiration-induced mismatches between the CT and the PET. Furthermore, PET/CT misregistration may bias the PET tracer distribution following CT-based attenuation correction (CT-AC). With the introduction of multi-row CT technology of up to 16 detector rows into PET/CT designs, we investigated the incidence of respiration artifacts in WB PET/CT examinations of patients who were unable to follow any breath-hold instructions.
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:chemical |
|
pubmed:status |
MEDLINE
|
pubmed:month |
Dec
|
pubmed:issn |
1619-7070
|
pubmed:author |
pubmed-author:BeyerThomasT,
pubmed-author:BockischAndreasA,
pubmed-author:DifilippoFrank PFP,
pubmed-author:KühlHilmarH,
pubmed-author:MüllerStefan PSP,
pubmed-author:MawlawiOsamaO,
pubmed-author:RobertsFionaF,
pubmed-author:RosenbaumSandraS,
pubmed-author:SchöderHeikoH,
pubmed-author:StattausJörgJ,
pubmed-author:VeitPatrickP
|
pubmed:issnType |
Print
|
pubmed:volume |
32
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1429-39
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:16133383-Adolescent,
pubmed-meshheading:16133383-Adult,
pubmed-meshheading:16133383-Aged,
pubmed-meshheading:16133383-Aged, 80 and over,
pubmed-meshheading:16133383-Artifacts,
pubmed-meshheading:16133383-Biotechnology,
pubmed-meshheading:16133383-Equipment Failure Analysis,
pubmed-meshheading:16133383-Female,
pubmed-meshheading:16133383-Fluorodeoxyglucose F18,
pubmed-meshheading:16133383-Humans,
pubmed-meshheading:16133383-Image Enhancement,
pubmed-meshheading:16133383-Image Interpretation, Computer-Assisted,
pubmed-meshheading:16133383-Male,
pubmed-meshheading:16133383-Middle Aged,
pubmed-meshheading:16133383-Movement,
pubmed-meshheading:16133383-Positron-Emission Tomography,
pubmed-meshheading:16133383-Radiography, Abdominal,
pubmed-meshheading:16133383-Radiography, Thoracic,
pubmed-meshheading:16133383-Radiopharmaceuticals,
pubmed-meshheading:16133383-Reproducibility of Results,
pubmed-meshheading:16133383-Respiratory Mechanics,
pubmed-meshheading:16133383-Retrospective Studies,
pubmed-meshheading:16133383-Sensitivity and Specificity,
pubmed-meshheading:16133383-Subtraction Technique,
pubmed-meshheading:16133383-Tomography, X-Ray Computed,
pubmed-meshheading:16133383-Transducers
|
pubmed:year |
2005
|
pubmed:articleTitle |
Respiration artifacts in whole-body (18)F-FDG PET/CT studies with combined PET/CT tomographs employing spiral CT technology with 1 to 16 detector rows.
|
pubmed:affiliation |
Department of Nuclear Medicine, University Hospital Essen, Hufelandstrasse 55, 45122 Essen, Germany. thomas.beyer@uni-essen.de
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Multicenter Study,
Evaluation Studies
|