pubmed:abstractText
Co-registration accuracy in combined whole-body (WB) PET/CT imaging is impaired by respiration-induced mismatches between the CT and the PET. Furthermore, PET/CT misregistration may bias the PET tracer distribution following CT-based attenuation correction (CT-AC). With the introduction of multi-row CT technology of up to 16 detector rows into PET/CT designs, we investigated the incidence of respiration artifacts in WB PET/CT examinations of patients who were unable to follow any breath-hold instructions.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Dec
pubmed:issn
1619-7070
pubmed:author
pubmed:issnType
Print
pubmed:volume
32
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1429-39
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed-meshheading:16133383-Adolescent, pubmed-meshheading:16133383-Adult, pubmed-meshheading:16133383-Aged, pubmed-meshheading:16133383-Aged, 80 and over, pubmed-meshheading:16133383-Artifacts, pubmed-meshheading:16133383-Biotechnology, pubmed-meshheading:16133383-Equipment Failure Analysis, pubmed-meshheading:16133383-Female, pubmed-meshheading:16133383-Fluorodeoxyglucose F18, pubmed-meshheading:16133383-Humans, pubmed-meshheading:16133383-Image Enhancement, pubmed-meshheading:16133383-Image Interpretation, Computer-Assisted, pubmed-meshheading:16133383-Male, pubmed-meshheading:16133383-Middle Aged, pubmed-meshheading:16133383-Movement, pubmed-meshheading:16133383-Positron-Emission Tomography, pubmed-meshheading:16133383-Radiography, Abdominal, pubmed-meshheading:16133383-Radiography, Thoracic, pubmed-meshheading:16133383-Radiopharmaceuticals, pubmed-meshheading:16133383-Reproducibility of Results, pubmed-meshheading:16133383-Respiratory Mechanics, pubmed-meshheading:16133383-Retrospective Studies, pubmed-meshheading:16133383-Sensitivity and Specificity, pubmed-meshheading:16133383-Subtraction Technique, pubmed-meshheading:16133383-Tomography, X-Ray Computed, pubmed-meshheading:16133383-Transducers
pubmed:year
2005
pubmed:articleTitle
Respiration artifacts in whole-body (18)F-FDG PET/CT studies with combined PET/CT tomographs employing spiral CT technology with 1 to 16 detector rows.
pubmed:affiliation
Department of Nuclear Medicine, University Hospital Essen, Hufelandstrasse 55, 45122 Essen, Germany. thomas.beyer@uni-essen.de
pubmed:publicationType
Journal Article, Comparative Study, Multicenter Study, Evaluation Studies