pubmed:abstractText
The European procedural guidelines for radionuclide imaging of myocardial perfusion and viability are presented in 13 sections covering patient information, radiopharmaceuticals, injected activities and dosimetry, stress tests, imaging protocols and acquisition, quality control and reconstruction methods, gated studies and attenuation-scatter compensation, data analysis, reports and image display, and positron emission tomography. If the specific recommendations given could not be based on evidence from original, scientific studies, we tried to express this state-of-art. The guidelines are designed to assist in the practice of performing, interpreting and reporting myocardial perfusion SPET. The guidelines do not discuss clinical indications, benefits or drawbacks of radionuclide myocardial imaging compared to non-nuclear techniques, nor do they cover cost benefit or cost effectiveness.
pubmed:commentsCorrections
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Jul
pubmed:issn
1619-7070
pubmed:author
pubmed:issnType
Print
pubmed:volume
32
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
855-97
pubmed:dateRevised
2007-11-15
pubmed:meshHeading
pubmed:year
2005
pubmed:articleTitle
EANM/ESC procedural guidelines for myocardial perfusion imaging in nuclear cardiology.
pubmed:affiliation
Department of Clinical Physiology and Nuclear Medicine, Rigshospitalet, University Hospital of Copenhagen, Copenhagen, Denmark. bhesse@rh.hosp.dk
pubmed:publicationType
Journal Article, Guideline, Research Support, Non-U.S. Gov't