Source:http://linkedlifedata.com/resource/pubmed/id/15880625
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
11
|
pubmed:dateCreated |
2005-6-1
|
pubmed:abstractText |
Py-1 and Py-6 are novel amino-reactive fluorescent reagents. The names given to them reflect that they consist of a pyrylium group attached to small aromatic moieties. Upon reaction with a primary amine there is a large spectral shift in the reagent, rendering them effectively fluorogenic. In this study, these reagents were used to label a test protein, (human serum albumin), and the sample was analyzed by capillary electrophoresis and laser-induced fluorescence detection. Detection limits after a 60 min labeling reaction at 22 degrees C (Py-1) and 50 degrees C (Py-6) were 6.5 ng/mL (98 pM) for Py-1 and 1.2 ng/mL (18 pM) for Py-6. Separation of immunoglobulin G (IgG), human serum albumin, lipase, and myoglobin after labeling with Py-6 were performed. The method was further modified to make it amenable to automation. Unlike many other amino reactive reagents used to label protein amino groups, reaction with Py-1 and Py-6 do not alter the charge of the protein and the advantage of this with respect to electrophoretic separations is discussed.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Amines,
http://linkedlifedata.com/resource/pubmed/chemical/Fluorescent Dyes,
http://linkedlifedata.com/resource/pubmed/chemical/Immunoglobulin G,
http://linkedlifedata.com/resource/pubmed/chemical/Lipase,
http://linkedlifedata.com/resource/pubmed/chemical/Myoglobin,
http://linkedlifedata.com/resource/pubmed/chemical/Proteins,
http://linkedlifedata.com/resource/pubmed/chemical/Serum Albumin
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
0173-0835
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
26
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
2208-13
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:15880625-Amines,
pubmed-meshheading:15880625-Electrophoresis, Capillary,
pubmed-meshheading:15880625-Fluorescent Dyes,
pubmed-meshheading:15880625-Humans,
pubmed-meshheading:15880625-Immunoglobulin G,
pubmed-meshheading:15880625-Lasers,
pubmed-meshheading:15880625-Lipase,
pubmed-meshheading:15880625-Myoglobin,
pubmed-meshheading:15880625-Proteins,
pubmed-meshheading:15880625-Serum Albumin
|
pubmed:year |
2005
|
pubmed:articleTitle |
Determination of picomolar concentrations of proteins using novel amino reactive chameleon labels and capillary electrophoresis laser-induced fluorescence detection.
|
pubmed:affiliation |
Institute of Analytical Chemistry, Chemo- and Biosensors, University of Regensburg, Regensburg, Germany. d.craig@uwinnipeg.ca
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|