Source:http://linkedlifedata.com/resource/pubmed/id/15856489
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
10
|
pubmed:dateCreated |
2005-12-5
|
pubmed:abstractText |
A simple, rapid, sensitive and specific liquid chromatography-tandem mass spectrometry method was developed and validated for quantification of hydrochlorothiazide (I), a common diuretic and anti-hypertensive agent. The analyte and internal standard, tamsulosin (II) were extracted by liquid-liquid extraction with diethyl ether-dichloromethane (70:30, v/v) using a Glas-Col Multi-Pulse Vortexer. The chromatographic separation was performed on a reversed-phase column (Waters symmetry C18) with a mobile phase of 10 mm ammonium acetate-methanol (15:85, v/v). The protonated analyte was quantitated in negative ionization by multiple reaction monitoring with a mass spectrometer. The mass transitions m/z 296.1 solidus in circle 205.0 and m/z 407.2 solidus in circle 184.9 were used to measure I and II, respectively. The assay exhibited a linear dynamic range of 0.5-200 ng/mL for hydrochlorothiazide in human plasma. The lower limit of quantitation was 500 pg/mL, with a relative standard deviation of less than 9%. Acceptable precision and accuracy were obtained for concentrations over the standard curve ranges. A run time of 2.5 min for each sample made it possible to analyze a throughput of more than 400 human plasma samples per day. The validated method has been successfully used to analyze human plasma samples for application in pharmacokinetic, bioavailability or bioequivalence studies.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Dec
|
pubmed:issn |
0269-3879
|
pubmed:author | |
pubmed:copyrightInfo |
(c) 2005 John Wiley & Sons, Ltd.
|
pubmed:issnType |
Print
|
pubmed:volume |
19
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
751-60
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:15856489-Antidiuretic Agents,
pubmed-meshheading:15856489-Antihypertensive Agents,
pubmed-meshheading:15856489-Chromatography, High Pressure Liquid,
pubmed-meshheading:15856489-Drug Stability,
pubmed-meshheading:15856489-Humans,
pubmed-meshheading:15856489-Hydrochlorothiazide,
pubmed-meshheading:15856489-Mass Spectrometry,
pubmed-meshheading:15856489-Reproducibility of Results,
pubmed-meshheading:15856489-Sensitivity and Specificity
|
pubmed:year |
2005
|
pubmed:articleTitle |
Sensitive liquid chromatography-tandem mass spectrometry method for quantification of hydrochlorothiazide in human plasma.
|
pubmed:affiliation |
Biopharmaceutical Research, Suven Life Sciences Ltd, Serene Chambers, Road 7, Banjara Hills, Hyderabad 500034, India. nvsrk@suven.com
|
pubmed:publicationType |
Journal Article,
Validation Studies
|