Source:http://linkedlifedata.com/resource/pubmed/id/15844835
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
1
|
pubmed:dateCreated |
2005-4-22
|
pubmed:abstractText |
Our previous study revealed that the coefficient of variation of harmonic magnitude (HCV) of radial arterial pulse was significantly raised before the death of cancer patients. In this study, we recorded the caudate arterial pulse of 24 Sprague-Dawley rats that had a fatal dose of urethane injected into their abdomens. Twenty rats were dead within 3 hours after the injection and four survived. We defined the last 100 minutes of each rat's life as the dying process. During the dying process, we found that both the systolic blood pressure and diastolic blood pressure dropped steeply during the last 5 minutes. However, all HCVs, except HCV1, climbed steeply before the last 5 minutes. The HCV1 of the dying rats was significantly higher than that of rats that survived, starting from the first minute (P < 0.01). The HCV2 of the dying rats was significantly higher than that of the survived rats starting from the 52nd minute (P < 0.05). The HCV3 and HCV4 of the dying rats were significantly higher than those of the survived rats until the 70th minute and the 80th minute, respectively (P < 0.05). Furthermore, HCV2-HCV4 proceeded with the dying process and increased gradually. We concluded that HCVs, which failed first in the high-frequency components and then in the low-frequency components, could provide physicians with earlier information to prevent the coming failure of circulatory system, and could reflect quantitatively pathological severity and predict patient outcome. The specific Fourier components in the pulse provide more physiological information than systolic and diastolic blood pressures.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:issn |
0192-415X
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
33
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
73-85
|
pubmed:meshHeading |
pubmed-meshheading:15844835-Acute Disease,
pubmed-meshheading:15844835-Animals,
pubmed-meshheading:15844835-Blood Pressure,
pubmed-meshheading:15844835-Carcinogens,
pubmed-meshheading:15844835-Death,
pubmed-meshheading:15844835-Fourier Analysis,
pubmed-meshheading:15844835-Heart Rate,
pubmed-meshheading:15844835-Injections, Intraperitoneal,
pubmed-meshheading:15844835-Overdose,
pubmed-meshheading:15844835-Radial Artery,
pubmed-meshheading:15844835-Rats,
pubmed-meshheading:15844835-Rats, Sprague-Dawley,
pubmed-meshheading:15844835-Urethane,
pubmed-meshheading:15844835-Yin-Yang
|
pubmed:year |
2005
|
pubmed:articleTitle |
Raising harmonic variation of arterial pulse in dying rats.
|
pubmed:affiliation |
Department of Electric Engineering, National Taiwan University, Taipei, Taiwan.
|
pubmed:publicationType |
Journal Article
|