pubmed:abstractText |
In 2001, the Committee on Standardization of Laboratory Testing Related to Diabetes Mellitus of the Japan Diabetes Society (JDS) prepared and certified a new reference material for haemoglobin A1c (HbA1c), Lot 2. The standardization programme for HbA1c measurement in Japan is currently based on Lot 2, although some laboratories still use the previous material (Lot 1). The values assigned to Lot 2 were based on the consensus values for Lot 1 and should give the same results. Therefore, there should be no difference in the measured values no matter which calibrators are used. The Committee conducted a domestic survey in order to confirm this relationship.
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:chemical |
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0004-5632
|
pubmed:author |
pubmed-author:AonoYukukoY,
pubmed-author:HoshinoTadaoT,
pubmed-author:KuwaKatsuhikoK,
pubmed-author:KuwashimaMasamichiM,
pubmed-author:MakinoHideichiH,
pubmed-author:OnoJunkoJ,
pubmed-author:SankeTokioT,
pubmed-author:ShimatsuAkiraA,
pubmed-author:TakeiIzumiI,
pubmed-author:TaminatoTomohikoT,
pubmed-author:TominagaMakotoM,
pubmed-author:UmemotoMasaoM,
pubmed-author:YoshinoGenG
|
pubmed:issnType |
Print
|
pubmed:volume |
42
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
47-50
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:15802032-Blood Chemical Analysis,
pubmed-meshheading:15802032-Calibration,
pubmed-meshheading:15802032-Chromatography, High Pressure Liquid,
pubmed-meshheading:15802032-Diabetes Mellitus,
pubmed-meshheading:15802032-Hemoglobin A, Glycosylated,
pubmed-meshheading:15802032-Humans,
pubmed-meshheading:15802032-Immunoassay,
pubmed-meshheading:15802032-Japan,
pubmed-meshheading:15802032-Laboratories,
pubmed-meshheading:15802032-Quality Control,
pubmed-meshheading:15802032-Reference Standards,
pubmed-meshheading:15802032-Reproducibility of Results,
pubmed-meshheading:15802032-Sensitivity and Specificity
|
pubmed:year |
2005
|
pubmed:articleTitle |
Japanese standard reference material JDS Lot 2 for haemoglobin A1c. II: Present state of standardization of haemoglobin A1c in Japan using the new reference material in routine clinical assays.
|
pubmed:affiliation |
Department of Laboratory Medicine, Yamagata University School of Medicine, 2-2-2 Iida-Nishi, Yamagata 990-9585, Japan. mtominag@med.id.yamagata-u.ac.jp
|
pubmed:publicationType |
Journal Article,
Comparative Study
|