pubmed:abstractText
Knowledge of the mechanical behaviour of immature tracheae is crucial in order to understand the effects exerted on central airways by ventilatory treatments, particularly of Total Liquid Ventilation. In this study, a combined experimental and computational approach was adopted to investigate the compliance and particularly collapsibility of preterm lamb tracheae in the range of pressure likely applied during Total Liquid Ventilation (-30 to 30 cmH2O). Tracheal samples of preterm lambs (n = 5; gestational age 120-130 days) were tested by altering transmural pressure from -30 to 30 cmH2O. Inflation (Si) and collapsing (Sc) compliance values were calculated in the ranges 0 to 10 cmH2O and -10 to 0 cmH2O, respectively. During the tests, an asymmetric behaviour of the DeltaV/V0 vs. P curves at positive and negative pressure was observed, with mean Si = 0.013 cmH2O(-1) and Sc = 0.053 cmH2O(-1). A different deformed configuration of the sample regions was observed, depending on the posterior shape of cartilaginous ring. A three-dimensional finite-element structural model of a single tracheal ring, based on histology measurements of the tested samples was developed. The model was parameterised in order to represent rings belonging to three different tracheal regions (craniad, median, caudal) and numerical analyses replicating the collapse test conditions were performed to evaluate the ring collapsibility at pressures between 0 and -30 cmH2O. Simulation results were compared to experimental data to verify the model's reliability. The best model predictions occurred at pressures -30 to -10 cmH2O. In this range, a model composed of median rings best interpreted the experimental data, with a maximum error of 2.7%; a model composed of an equal combination of all rings yielded an error of 12.6%.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Dec
pubmed:issn
0021-9290
pubmed:author
pubmed:issnType
Print
pubmed:volume
37
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1837-47
pubmed:dateRevised
2009-11-11
pubmed:meshHeading
pubmed:year
2004
pubmed:articleTitle
A numerical and experimental study of compliance and collapsibility of preterm lamb tracheae.
pubmed:affiliation
Department of Bioengineering, Politecnico di Milano, Piazza Leonardo da Vinci, 32, Milan 20133, Italy. costantino@biomed.polimi.it
pubmed:publicationType
Journal Article, In Vitro