Source:http://linkedlifedata.com/resource/pubmed/id/15499662
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
22
|
pubmed:dateCreated |
2004-11-3
|
pubmed:abstractText |
An electrospray ionization tandem mass spectrometry (ESI-MS/MS) system with an online dual-loop cleanup device was developed for simultaneous quantitation of the urinary benzene exposure biomarkers trans,trans-muconic acid (ttMA) and S-phenylmercapturic acid (SPMA). The cleanup device was constructed from an autosampler, two electrically operated two-position switching valves, a reversed-phase C18 trap cartridge, a 200-microL loop, and two solvent-delivery pumps. The device was interfaced directly with a triple-quadrupole mass spectrometer and fully controlled by computer software and hardware. Because isotope dilution by introducing 13C-labeled ttMA and SPMA as internal standards was employed, the precision of the analytical system was high (for ttMA, intra- and inter-day CV values ranged from 3.82-4.53%; for SPMA, 2.13-7.06%). The calibration curves obtained using human urine spiked with ttMA were linear from 15.6-4000 microg/L (R = 0.9998) and SPMA at concentrations from 0.78-200 microg/L (R = 0.9993). The method detection limit (MDL) for SPMA was 0.23 microg/L. The MDL of ttMA could not be determined accurately because of unavailability of an appropriate blank urine matrix, but was estimated to be lower than 7.43 microg/L. Without tedious manual sample cleanup procedures the analytical system is fully automated and is therefore useful for high-throughput simultaneous determination of urinary ttMA and SPMA. The sample throughput is roughly 100 samples per day. With the selectivity and the sensitivity provided by MS/MS detection, the analytical system can be used for large-scale monitoring of environmental or occupational exposure of humans to benzene.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Acetylcysteine,
http://linkedlifedata.com/resource/pubmed/chemical/Benzene,
http://linkedlifedata.com/resource/pubmed/chemical/Benzene Derivatives,
http://linkedlifedata.com/resource/pubmed/chemical/Biological Markers,
http://linkedlifedata.com/resource/pubmed/chemical/S-phenyl-N-acetylcysteine,
http://linkedlifedata.com/resource/pubmed/chemical/Sorbic Acid,
http://linkedlifedata.com/resource/pubmed/chemical/muconic acid
|
pubmed:status |
MEDLINE
|
pubmed:issn |
0951-4198
|
pubmed:author | |
pubmed:copyrightInfo |
Copyright (c) 2004 John Wiley & Sons, Ltd.
|
pubmed:issnType |
Print
|
pubmed:volume |
18
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
2743-52
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:15499662-Acetylcysteine,
pubmed-meshheading:15499662-Benzene,
pubmed-meshheading:15499662-Benzene Derivatives,
pubmed-meshheading:15499662-Biological Markers,
pubmed-meshheading:15499662-Computers,
pubmed-meshheading:15499662-Occupational Exposure,
pubmed-meshheading:15499662-Reproducibility of Results,
pubmed-meshheading:15499662-Sensitivity and Specificity,
pubmed-meshheading:15499662-Software,
pubmed-meshheading:15499662-Sorbic Acid,
pubmed-meshheading:15499662-Spectrometry, Mass, Electrospray Ionization
|
pubmed:year |
2004
|
pubmed:articleTitle |
An electrospray ionization tandem mass spectrometry based system with an online dual-loop cleanup device for simultaneous quantitation of urinary benzene exposure biomarkers trans,trans-muconic acid and S-phenylmercapturic acid.
|
pubmed:affiliation |
Department of Environmental and Occupational Health, College of Medicine, National Cheng Kung University, Tainan 704, Taiwan.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|