Source:http://linkedlifedata.com/resource/pubmed/id/15468992
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2004-10-7
|
pubmed:abstractText |
To determine the reliability of the vestibolo-ocular reflex test measured via Vorteq, 16 subjects underwent head-autorotation test at the frequencies 1-5 Hz. All patients underwent the re-test. No linear correlation was observed between the measurements, i.e., no repeatability of the same measurements at the various frequencies. The Head Auto-Rotation Test by Vorteq has demonstrated advantages: patients are not disturbed by the active head movements; the full test protocol, lasts only a few minutes; the method enables the vestibolo-ocular reflex to be evaluated at high head-rotation frequencies. However, the test has disadvantages: poor test-retest inter-individual repeatability, wide standard deviations of results with heterogeneous inter-individual spread with regard to phase and asymmetry values especially at high rotation frequencies. In the light of the above findings, it can be seen that the test-retest of the Vorteq system is not sufficiently reliable and hence cannot be used in clinical practice.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
0392-100X
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
24
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
58-62
|
pubmed:dateRevised |
2009-7-23
|
pubmed:meshHeading |
pubmed-meshheading:15468992-Adult,
pubmed-meshheading:15468992-Data Interpretation, Statistical,
pubmed-meshheading:15468992-Electronystagmography,
pubmed-meshheading:15468992-Female,
pubmed-meshheading:15468992-Head Movements,
pubmed-meshheading:15468992-Humans,
pubmed-meshheading:15468992-Male,
pubmed-meshheading:15468992-Middle Aged,
pubmed-meshheading:15468992-Reflex, Vestibulo-Ocular,
pubmed-meshheading:15468992-Rotation,
pubmed-meshheading:15468992-Time Factors,
pubmed-meshheading:15468992-Vertigo,
pubmed-meshheading:15468992-Vestibular Function Tests
|
pubmed:year |
2004
|
pubmed:articleTitle |
Test-retest reliability of the VOR as measured via Vorteq in healthy subjects.
|
pubmed:affiliation |
Department of Otorhinolaryngology, Head and Neck Surgery, University of Trieste, Cattinara Hospital, Trieste, Italy. tirellig@units.it
|
pubmed:publicationType |
Journal Article,
Comparative Study,