pubmed:abstractText
First derivative of arterial blood pressure, dp/dt is known to reflect the contractility power of the heart. We hypothesize that the calculated area under each cardiac cycle of the blood pressure curve is also another practical tool in revealing the heart contractility power. Of the 84 subjects, 61 patients were found to have adequate contractility power (high dp/dt) and their mean area calculation resulted in 64.2 mmHg s with a standard deviation of 2.9 mmHg s. The remaining 23 patients have indicated poor heart contractility power (low dp/dt) and stayed in serious condition for long time. This group had mean area of 41.4 +/- 3.1 mmHg s. Patients with poor contractility power had areas below 45 mmHg s, while all area calculations for patients with high contractility power stayed over 60 mmHg s. Therefore, small area of the arterial blood pressure curves seems to be a good indicator of a poor heart contractility power and the area calculation may be an adjunct parameter to the dp/dt that has been employed for the assessment of heart contractility.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Nov
pubmed:issn
0169-2607
pubmed:author
pubmed:issnType
Print
pubmed:volume
76
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
177-80
pubmed:dateRevised
2008-11-21
pubmed:meshHeading
pubmed:year
2004
pubmed:articleTitle
Investigation of a new heart contractility power parameter.
pubmed:affiliation
Electronics Engineering Department, Erciyes University, 38039 Kayseri, Turkey. kara@erciyes.edu.tr
pubmed:publicationType
Journal Article, Validation Studies