pubmed:abstractText
The elliptical centric (EC) view order samples a 3DFT acquisition from the center of k-space outward, and when applied to contrast-enhanced MR angiography (CE-MRA) provides intrinsic venous suppression. This is because the veins enhance several seconds after the scan is initiated, and are thus encoded solely by noncentral k-space frequencies. A separate method, sensitivity encoding (SENSE), accelerates the k-space sampling rate by reducing the phase FOV or, equivalently, by increasing the k-space sampling interval, and has been used to increase spatiotemporal resolution. We hypothesized that by combining SENSE with EC, sampling of central k-space would be accelerated and the k-space radius at which the veins first showed contrast enhancement would be increased over a reference scan, thus providing improved venous suppression and spatial resolution without additional scan time. This hypothesis was studied with the use of phantom and carotid CE-MRA experiments, and the results demonstrated an approximate 25% reduction in venous signal when SENSE was used.
pubmed:grant
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-10542355, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-11050636, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-11378895, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-11559518, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-11948840, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-12594723, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-12648798, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-8134563, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-8280977, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-8835958, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-8875408, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-9314975, http://linkedlifedata.com/resource/pubmed/commentcorrection/15389954-9660549
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Oct
pubmed:issn
0740-3194
pubmed:author
pubmed:issnType
Print
pubmed:volume
52
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
761-5
pubmed:dateRevised
2011-3-7
pubmed:meshHeading
pubmed:year
2004
pubmed:articleTitle
Improved venous suppression and spatial resolution with SENSE in elliptical centric 3D contrast-enhanced MR angiography.
pubmed:affiliation
Magnetic Resonance Imaging Laboratory, Department of Radiology, Mayo Clinic College of Medicine, Rochester, Minnesota 55905, USA.
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, P.H.S., Research Support, Non-U.S. Gov't