Source:http://linkedlifedata.com/resource/pubmed/id/15370613
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
6
|
pubmed:dateCreated |
2004-9-16
|
pubmed:abstractText |
Since 2001, 50 breast cancer patients, for whom extensive lung/heart involvement was expected from the use of conventional tangential 2-field technique (2F) owing to complex anatomies, were irradiated using a 3-field conformal technique (3F). Dose plans were designed for both 3F and 2F and a dose volume histogram analysis on ipsilateral lung, heart, and target was conducted. The 3F technique allowed a significant reduction in ipsilateral lung irradiation: mean dose dropped from 16.0+/-3.8 (2F) to 12.0+/-2.7 Gy (3F) and V(45Gy) from 20.7+/-6.8 (2F) to 3.2+/-2.9% (3F). Similarly, in patients irradiated to the left breast, heart mean dose was reduced from 8.1 Gy (2F) to 6.8 Gy (3F) and D(15%) from 19.0 Gy to 14.0 Gy. All differences reached a high degree of significance. The target coverage was not clinically compromised since the slight reduction using 3F compared with 2F is limited to V(95%) while V(90%) difference, even if statistically significant, is small: 98.2+/-1.8% (3F) and 98.8+/-1.6 (2F). A preliminary report on clinical follow up is also included; with a mean follow up of 15.8 months, no pulmonary or cardiac complications were observed.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:issn |
0284-186X
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
43
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
558-66
|
pubmed:dateRevised |
2009-5-12
|
pubmed:meshHeading |
pubmed-meshheading:15370613-Aged,
pubmed-meshheading:15370613-Breast Neoplasms,
pubmed-meshheading:15370613-Female,
pubmed-meshheading:15370613-Humans,
pubmed-meshheading:15370613-Lung Neoplasms,
pubmed-meshheading:15370613-Male,
pubmed-meshheading:15370613-Mastectomy, Segmental,
pubmed-meshheading:15370613-Middle Aged,
pubmed-meshheading:15370613-Neoplasm Invasiveness,
pubmed-meshheading:15370613-Radiation Injuries,
pubmed-meshheading:15370613-Radiotherapy, Adjuvant,
pubmed-meshheading:15370613-Radiotherapy, Conformal,
pubmed-meshheading:15370613-Risk Factors
|
pubmed:year |
2004
|
pubmed:articleTitle |
Breast irradiation with three conformal photon fields for patients with high lung involvement.
|
pubmed:affiliation |
Medical Physics Unit, Department of Physics Oncology, Institute of Southern Switzerland, University of Milan, Bellinzona, Switzerland. lucozzi@iosi.ch
|
pubmed:publicationType |
Journal Article,
Clinical Trial
|