Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
1-4
pubmed:dateCreated
2004-9-8
pubmed:abstractText
A recoil-proton spectrometer was created by coupling a p-i-n diode with a polyethylene converter. The maximum detectable energy, imposed by the thickness of the totally depleted layer, is approximately 6 MeV. The minimum detectable energy is limited by the contribution of secondary electrons generated by photons in the detector assembly. This limit is approximately 1.5 MeV at full-depletion voltage and was decreased using pulse-shape discrimination. The diode was set up in the 'reverse-injection' configuration (i.e. with the N+ layer adjacent to the converter). This configuration provides longer collection times for the electron-hole pairs generated by the recoil-protons. The pulse-shape discrimination was based on the zero-crossing time of bipolar signals from a (CR)2-(RC)2 filter. The detector was characterised using monoenergetic neutrons generated in the Van De Graaff CN accelerator at the INFN-Laboratori Nazionali di Legnaro. The energy limit for discrimination proved to be approximately 900 keV.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
0144-8420
pubmed:author
pubmed:issnType
Print
pubmed:volume
110
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
509-16
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed-meshheading:15353700-Body Burden, pubmed-meshheading:15353700-Equipment Design, pubmed-meshheading:15353700-Equipment Failure Analysis, pubmed-meshheading:15353700-Feasibility Studies, pubmed-meshheading:15353700-Humans, pubmed-meshheading:15353700-Linear Energy Transfer, pubmed-meshheading:15353700-Neutrons, pubmed-meshheading:15353700-Protons, pubmed-meshheading:15353700-Radiation Dosage, pubmed-meshheading:15353700-Radiation Protection, pubmed-meshheading:15353700-Radiometry, pubmed-meshheading:15353700-Relative Biological Effectiveness, pubmed-meshheading:15353700-Reproducibility of Results, pubmed-meshheading:15353700-Risk Assessment, pubmed-meshheading:15353700-Risk Factors, pubmed-meshheading:15353700-Semiconductors, pubmed-meshheading:15353700-Sensitivity and Specificity, pubmed-meshheading:15353700-Signal Processing, Computer-Assisted, pubmed-meshheading:15353700-Spectrum Analysis
pubmed:year
2004
pubmed:articleTitle
A recoil-proton spectrometer based on a p-i-n diode implementing pulse-shape discrimination.
pubmed:affiliation
Dipartimento di Ingegneria Nucleare, Politecnico di Milano, via Ponzio 34/3, 20133 Milano, Italy. stefano.agosteo@polimi.it
pubmed:publicationType
Journal Article, Comparative Study, Research Support, Non-U.S. Gov't, Evaluation Studies, Validation Studies