Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
4
pubmed:dateCreated
2004-3-25
pubmed:abstractText
Flow dialysis has found widespread use in determining the dissociation constant (KD) of a protein-ligand interaction or the amount of available binding sites (E0). This method has the potency to measure both these parameters in a single experiment and in this article a method to measure simultaneously the KD and E0 is presented, together with an extensive error analysis of the method. The flow-dialysis technique is experimentally simple to perform. However, a number of practical aspects of this method can have a large impact on the outcome of KD and E0. We have investigated all sources of significant systematic and random errors, using the interaction between mannitol and its transporter from Escherichia coli as a model. Monte Carlo simulations were found to be an excellent tool to assess the impact of these errors on the binding parameters and to define the experimental conditions that allow their most accurate estimation.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-10433685, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-11583589, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-12054448, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-1390749, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-1610796, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-2125489, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-2125492, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-2723331, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-3239764, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-4773291, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-5768868, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-6967404, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-696998, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-7856859, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-7880818, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-7978263, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-8504105, http://linkedlifedata.com/resource/pubmed/commentcorrection/15041640-9328576
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Apr
pubmed:issn
0006-3495
pubmed:author
pubmed:issnType
Print
pubmed:volume
86
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1959-68
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
2004
pubmed:articleTitle
Evaluation of the flow-dialysis technique for analysis of protein-ligand interactions: an experimental and a monte carlo study.
pubmed:affiliation
Department of Biochemistry and Biophysical Chemistry, Groningen Biomolecular Science and Biotechnology Institute, University of Groningen, 9747 AG Groningen, The Netherlands.
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't