rdf:type |
|
lifeskim:mentions |
|
pubmed:issue |
Pt 2
|
pubmed:dateCreated |
2004-2-12
|
pubmed:abstractText |
An interpolating two-dimensional X-ray imaging detector based on a single-photon counter with gas amplification by GEM (gas electron multiplier) structures is presented. The detector system can be used for time-resolved structure research down to the micro s time domain. The prototype detector has been tested at the SAXS (small-angle X-ray scattering) beamline at ELETTRA synchrotron light source with a beam energy of 8 keV. The imaging performance is examined with apertures and standard diffraction targets. Finally, the application in a time-resolved lipid temperature-jump experiment is presented.
|
pubmed:language |
eng
|
pubmed:journal |
|
pubmed:citationSubset |
IM
|
pubmed:chemical |
|
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0909-0495
|
pubmed:author |
pubmed-author:AmenitschHeinzH,
pubmed-author:BernstorffSigridS,
pubmed-author:BeschHans JürgenHJ,
pubmed-author:MartoiuSorinS,
pubmed-author:MenkRalf HendrikRH,
pubmed-author:NurdanKivançK,
pubmed-author:OrthenAndreA,
pubmed-author:RappoltMichaelM,
pubmed-author:WagnerHendrikH,
pubmed-author:WalentaAlbert HeinrichAH,
pubmed-author:WerthenbachUlrichU
|
pubmed:issnType |
Print
|
pubmed:day |
1
|
pubmed:volume |
11
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
177-86
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:14960783-Animals,
pubmed-meshheading:14960783-Collagen,
pubmed-meshheading:14960783-Equipment Design,
pubmed-meshheading:14960783-Equipment Failure Analysis,
pubmed-meshheading:14960783-Fatty Acids,
pubmed-meshheading:14960783-Pilot Projects,
pubmed-meshheading:14960783-Radiographic Image Enhancement,
pubmed-meshheading:14960783-Radiometry,
pubmed-meshheading:14960783-Rats,
pubmed-meshheading:14960783-Reproducibility of Results,
pubmed-meshheading:14960783-Sensitivity and Specificity,
pubmed-meshheading:14960783-Synchrotrons,
pubmed-meshheading:14960783-Tendons,
pubmed-meshheading:14960783-Transducers,
pubmed-meshheading:14960783-X-Ray Diffraction,
pubmed-meshheading:14960783-X-Rays
|
pubmed:year |
2004
|
pubmed:articleTitle |
Development of a two-dimensional virtual-pixel X-ray imaging detector for time-resolved structure research.
|
pubmed:affiliation |
Universität Siegen, Fachbereich Physik, Emmy-Noether-Campus, Walter-Flex-Strasse 3, D-57072 Siegen, Germany. orthen@alwa02.physik.uni-siegen.de
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't,
Evaluation Studies,
Validation Studies
|