pubmed:abstractText |
In this paper, we propose a new, rapid, highly sensitive and reproducible RP-HPLC-FLD method for the detection of ochratoxin A (OTA) in wine, by directly injecting the liquid in the chromatographic system without any extraction or clean-up. An alkaline mobile phase (NH4Cl:CH-CN 85:15 (v/v), 20 mM, pH 9.8) was used to obtain a distinct fluorescence enhancement. This improvement allows to reach, without an immunoaffinity clean-up or concentration, a detection limit of 0.05 ng/ml, which is similar to those commonly obtained after immunoaffinity purification and acidic elution. The method was statistically validated and directly applied to a series of wine samples.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
0021-9673
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
23
|
pubmed:volume |
1024
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
275-9
|
pubmed:dateRevised |
2009-1-15
|
pubmed:meshHeading | |
pubmed:year |
2004
|
pubmed:articleTitle |
Reversed-phase liquid chromatographic method for the determination of ochratoxin A in wine.
|
pubmed:affiliation |
Dipartimento di Chimica Organica e Industriale, Università degli Studi di Parma, Parco Area delle Scienze 17/A, I-43100 Parma, Italy.
|
pubmed:publicationType |