Source:http://linkedlifedata.com/resource/pubmed/id/14663544
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2004-1-9
|
pubmed:abstractText |
A chemiluminescence signal at 425 nm was observed when ferric state myoglobin was mixed with luminol in alkaline medium. Because the signal was remarkably enhanced in the presence of Fe(CN)6(4-), analytical applications were investigated in a flow-injection system. The increase in chemiluminescence was linearly dependent on myoglobin concentration in the range 0.1 to 100 nmol L(-1), and the limit of detection was 0.04 nmol L(-1) with relative standard deviation 3.2% (3 sigma). It was also found that binding of Mb with the ligands CN-, SCN-, and F- significantly inhibited the chemiluminescence reaction. The linear dynamic ranges for the ligands were 1.0-300.0, 0.1-3.0, and 0.5-100.0 nmol L(-1), and the limits of detection (S/N=3) 0.4, 0.04, and 0.2 nmol L(-1), for F-, CN-, and SCN-, respectively. The relative standard deviations were 5.32%, 6.13%, and 3.38% for 0.1 nmol L(-1) CN-, 0.5 nmol L(-1) SCN-, and 1.0 nmol L(-1) F-, respectively. At a flow rate of 2.0 mL min(-1) the assay could be accomplished in 1 min, including sampling and washing. The method has been successfully applied to the determination of myoglobin in human urine and F- in water samples. A possible mechanism of chemiluminescence production by myoglobin and luminol is presented.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/Ferric Compounds,
http://linkedlifedata.com/resource/pubmed/chemical/Fluorides,
http://linkedlifedata.com/resource/pubmed/chemical/Ligands,
http://linkedlifedata.com/resource/pubmed/chemical/Luminol,
http://linkedlifedata.com/resource/pubmed/chemical/Myoglobin,
http://linkedlifedata.com/resource/pubmed/chemical/Water
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jan
|
pubmed:issn |
1618-2642
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
378
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
529-35
|
pubmed:dateRevised |
2011-11-17
|
pubmed:meshHeading |
pubmed-meshheading:14663544-Female,
pubmed-meshheading:14663544-Ferric Compounds,
pubmed-meshheading:14663544-Flow Injection Analysis,
pubmed-meshheading:14663544-Fluorides,
pubmed-meshheading:14663544-Humans,
pubmed-meshheading:14663544-Ligands,
pubmed-meshheading:14663544-Luminescent Measurements,
pubmed-meshheading:14663544-Luminol,
pubmed-meshheading:14663544-Male,
pubmed-meshheading:14663544-Myoglobin,
pubmed-meshheading:14663544-Water
|
pubmed:year |
2004
|
pubmed:articleTitle |
A study of the chemiluminescence behavior of myoglobin with luminol and its analytical applications.
|
pubmed:affiliation |
Department of Chemistry, Northwest University, 710069 Xi'an, PR China. songzhenghua@hotmail.com
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|