Source:http://linkedlifedata.com/resource/pubmed/id/14568510
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2003-10-21
|
pubmed:abstractText |
Functional MRI studies are very sensitive to motion; head movements of as little as 1-mm translations or 1 degrees rotations may cause spurious signals. An algorithm was developed that uses k-space MRI data to monitor subject motion during functional MRI time series. A k-space weighted average of squared difference between the initial scan and subsequent scans is calculated, which summarizes subject motion in a single quality parameter; however, the quality parameter cannot be used for motion correction. The evolution of this quality parameter throughout a time series indicates whether head motion is within a predetermined limit. Fifty functional MRI studies were used to calibrate the sensitivity of the algorithm, using the six rigid-body registration parameters (three translations and three rotations) from the statistical parametric mapping (SPM99) package as a reference. The average correlation coefficient between the new quality parameter and the reference value from SPM was 0.84. The simple algorithm correctly classified acceptable or excessive motion with 90% accuracy, with the remaining 10% being borderline cases. This method makes it possible to evaluate brain motion within seconds after a scan and to decide whether a study needs to be repeated.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
1053-8119
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
20
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1411-8
|
pubmed:dateRevised |
2007-11-14
|
pubmed:meshHeading |
pubmed-meshheading:14568510-Algorithms,
pubmed-meshheading:14568510-Brain,
pubmed-meshheading:14568510-Calibration,
pubmed-meshheading:14568510-Head Movements,
pubmed-meshheading:14568510-Humans,
pubmed-meshheading:14568510-Image Processing, Computer-Assisted,
pubmed-meshheading:14568510-Magnetic Resonance Imaging,
pubmed-meshheading:14568510-Motion
|
pubmed:year |
2003
|
pubmed:articleTitle |
k-Space based summary motion detection for functional magnetic resonance imaging.
|
pubmed:affiliation |
Medical Department, Brookhaven National Laboratory, Upton, NY 11973, USA. caparelli@bnl.gov
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, P.H.S.,
Research Support, U.S. Gov't, Non-P.H.S.,
Research Support, Non-U.S. Gov't
|