pubmed:abstractText
Using the finite element method, this study modeled a 4.0 x 13.0-mm IMZ implant, restored with a cast gold crown, to examine the influence of the polyoxymethylene (POM) intramobile element (IME) on the transmission of vertical and oblique forces. Stress concentrations in the bone and in components of the implant system were much greater under a 30-degree load than under an equal vertical load. Stress transmission to bone occurred chiefly in the crestal region, and these stresses were not reduced when the IME was modeled in POM rather than in titanium. Maximum stress concentrations occurred in the fastening screw.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
D
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
0882-2786
pubmed:author
pubmed:issnType
Print
pubmed:volume
7
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
450-8
pubmed:dateRevised
2006-11-15
pubmed:meshHeading
pubmed:year
1992
pubmed:articleTitle
Comparison of stress transmission in the IMZ implant system with polyoxymethylene or titanium intramobile element: a finite element stress analysis.
pubmed:affiliation
Department of Family Dentistry, College of Dentistry, The University of Iowa, Iowa City.
pubmed:publicationType