pubmed:abstractText |
Two-dimensional (2-D) arrays have been proposed as a solution to the degradation in medical ultrasound image quality occurring as a result of asymmetric focusing properties of linear phased array transducers. The 2-D phased transducer array is also capable of electronically steering the symmetrically focused ultrasound beam throughout a three-dimensional volume. In a companion paper the potential of 2-D transducer arrays for medical imaging has been investigated using simulated B-scan images. In this paper, the advantages of 2-D over linear transducer arrays is demonstrated by simulating images of spherical cysts embedded in a large scattering volume. The large elevation beamwidth in the nearfield of a 5 MHz linear phased transducer array results in a severe reduction in the image contrast measured between a 4 mm diameter cyst and the surrounding scattering media. By employing a 2-D array with symmetric focusing, the contrast between the cyst and surrounding scatterers is significantly improved. The use of additional elements in the elevation direction of a linear array is also investigated. In this case the additional elements are included only to focus, but not to steer the ultrasound beam. Using the contrast characteristics of a 4 mm diameter cyst, it is shown that relatively few elevation elements are required to significantly improve the nearfield imaging capability of the linear array.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Oct
|
pubmed:issn |
0161-7346
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
14
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
344-53
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:1296338-Artifacts,
pubmed-meshheading:1296338-Cysts,
pubmed-meshheading:1296338-Humans,
pubmed-meshheading:1296338-Image Enhancement,
pubmed-meshheading:1296338-Models, Structural,
pubmed-meshheading:1296338-Technology, Radiologic,
pubmed-meshheading:1296338-Transducers,
pubmed-meshheading:1296338-Ultrasonography
|
pubmed:year |
1992
|
pubmed:articleTitle |
Simulation of B-scan images from two-dimensional transducer arrays: Part II--Comparisons between linear and two-dimensional phased arrays.
|
pubmed:affiliation |
Department of Medical Biophysics, University of Toronto, Ontario, Canada.
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Research Support, Non-U.S. Gov't
|