Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
9
|
pubmed:dateCreated |
1993-4-16
|
pubmed:abstractText |
Cutaneous electrogastrography (EGGc), the recording of gastric electrical activity from the cutaneous abdominal surface, still presents a series of difficulties connected with the interpretation of signals. In this study, the authors evaluated the reproducibility of electrogastrographic data over a period of time by making recordings on three consecutive days in a group of healthy subjects. The recordings (lasting 1 hour) were made in the morning on fasting subjects. Three sets of bipolar cutaneous electrodes were placed on the abdomen around the pyloric radiological projection and the couple 3-6 corresponded to the antral axis. The spectral analysis of data was computed by fast Fourier transform. Their data confirmed that the 3-6 couple, corresponding to the antral axis, provides the strongest EGG signal. Each subject's mean gastric frequency and power were evaluated on the three consecutive recording days. The mean frequency was 2.83 +/- 0.22, 2.89 +/- 0.23, and 2.86 +/- 0.16 cpm on day I, day II and day III respectively. The mean power was 54.80 +/- 21.34, 46.86 +/- 21.52 and 49.25 +/- 19.55 microV 2 on day I, day II and day III respectively. The analysis of variance showed that the mean gastric frequency and power were not significantly different on the three days (p > 0.05). This shows that the frequency of the EGGc signal remains stable in the course of time and hence that EGGc is a reliable method of studying disorders in gastric electrical rhythm.(ABSTRACT TRUNCATED AT 250 WORDS)
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Nov
|
pubmed:issn |
0369-8114
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
40
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
889-94
|
pubmed:dateRevised |
2004-11-17
|
pubmed:meshHeading |
pubmed-meshheading:1296162-Adult,
pubmed-meshheading:1296162-Aged,
pubmed-meshheading:1296162-Fasting,
pubmed-meshheading:1296162-Female,
pubmed-meshheading:1296162-Humans,
pubmed-meshheading:1296162-Male,
pubmed-meshheading:1296162-Middle Aged,
pubmed-meshheading:1296162-Reference Values,
pubmed-meshheading:1296162-Stomach
|
pubmed:year |
1992
|
pubmed:articleTitle |
Reproducibility of cutaneous electrogastrography in the fasting state in man.
|
pubmed:affiliation |
Laboratorio di Fisiopatologia Sperimentale, Istituto Scientifico Gastrenterologico, Castellana Grotte, BA, Italy.
|
pubmed:publicationType |
Journal Article
|