Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
4
pubmed:dateCreated
2003-9-1
pubmed:abstractText
Recording brain activity using positron emission tomography (PET) during the stimulation of different parts of the brain by transcranial magnetic stimulation (TMS) permits the mapping of neural connections in the living human brain. However, controversy remains regarding the need for micro-metal shielding of the PET scanner during magnetic stimulation. The aim of this study was to test the effects of magnetic fields generated by TMS on PET data acquisition. With TMS-on and -off in the PET field of view, transmission scans with a (68)Ge/(68)Ga pin source and emission scans with an uniform phantom filled with water and (18)F were acquired. The frequency and intensity of stimulation were set at 3-5 Hz and 70-80% of the maximum output of the stimulator, respectively. The TMS coil was placed at several locations inside the PET gantry, and the main field direction of the TMS coil was varied between parallel and perpendicular orientation to the scanner's axis. Qualitative and quantitative evaluation of the sinograms of transmission PET scans and reconstructed emission images indicated no measurable differences between TMS-on and -off and post-TMS conditions for any position or orientation. The long distance between the TMS coil and the detector block in the PET scanner, as well as the rapid reduction of the magnetic field with distance (3% of maximum field at 10 cm, in air), could explain the lack of TMS interference. The brief duration (approximately 250 micros) of the TMS pulses relative to the total PET acquisition time would also explain the lack of TMS effects. The lack of TMS effects on the PET scanner, as well as PET imaging without any shielding, has been reported by other laboratories.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Aug
pubmed:issn
1053-8119
pubmed:author
pubmed:issnType
Print
pubmed:volume
19
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1812-9
pubmed:dateRevised
2009-5-20
pubmed:meshHeading
pubmed:year
2003
pubmed:articleTitle
Positron emission tomography during transcranial magnetic stimulation does not require mu-metal shielding.
pubmed:affiliation
Department of Nuclear Medicine, Seoul National University College of Medicine, Seoul 110-744, South Korea.
pubmed:publicationType
Journal Article, Research Support, Non-U.S. Gov't, Evaluation Studies, Research Support, N.I.H., Extramural