Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
18
pubmed:dateCreated
2003-9-3
pubmed:abstractText
Dynamic nuclear polarization has enabled hyperpolarization of nuclei such as 13C and 15N in endogenous substances. The resulting high nuclear polarization makes it possible to perform subsecond 13C MRI. By using the dynamic nuclear polarization hyperpolarization technique, 10% polarization was obtained in an aqueous solution of 100 mM 13C-labeled urea, ready for injection. The in vivo T1 relaxation time of 13C in the urea solution was determined to 20 +/- 2 s. Due to the long relaxation time, it is possible to use the hyperpolarized substance for medical imaging. A series of high-resolution ( approximately 1-mm) magnetic resonance images were acquired, each with a scan time of 240 ms, 0-5 s after an i.v. injection of the hyperpolarized aqueous [13C]urea solution in a rat. The results show that it is possible to perform 13C angiography with a signal-to-noise ratio of approximately 275 in approximately 0.25 s. Perfusion studies with endogenous substances may allow higher spatial and/or temporal resolution than is possible with current proton imaging techniques.
pubmed:commentsCorrections
http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-11105032, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-11197982, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-11312184, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-11378886, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-11383873, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-11432577, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-11747007, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-12930897, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-2252604, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-3747821, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-7960627, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-8308748, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-9084082, http://linkedlifedata.com/resource/pubmed/commentcorrection/12930896-9498861
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Sep
pubmed:issn
0027-8424
pubmed:author
pubmed:issnType
Print
pubmed:day
2
pubmed:volume
100
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
10435-9
pubmed:dateRevised
2009-11-18
pubmed:meshHeading
pubmed:year
2003
pubmed:articleTitle
Molecular imaging with endogenous substances.
pubmed:affiliation
Amersham Health Research and Development AB, Medeon, SE-205 12 Malmö, Sweden. klaes.golman@amersham.com
pubmed:publicationType
Journal Article