pubmed-article:12734684 | rdf:type | pubmed:Citation | lld:pubmed |
pubmed-article:12734684 | lifeskim:mentions | umls-concept:C0087111 | lld:lifeskim |
pubmed-article:12734684 | lifeskim:mentions | umls-concept:C0920317 | lld:lifeskim |
pubmed-article:12734684 | lifeskim:mentions | umls-concept:C0027342 | lld:lifeskim |
pubmed-article:12734684 | lifeskim:mentions | umls-concept:C0009566 | lld:lifeskim |
pubmed-article:12734684 | lifeskim:mentions | umls-concept:C0162385 | lld:lifeskim |
pubmed-article:12734684 | lifeskim:mentions | umls-concept:C0443343 | lld:lifeskim |
pubmed-article:12734684 | lifeskim:mentions | umls-concept:C0699733 | lld:lifeskim |
pubmed-article:12734684 | pubmed:issue | 4 | lld:pubmed |
pubmed-article:12734684 | pubmed:dateCreated | 2003-8-13 | lld:pubmed |
pubmed-article:12734684 | pubmed:abstractText | The choice between dynamic screw-intramedullary nail (DSIN) devices and dynamic screw-plate (DSP) devices for the fixation of unstable trochanteric fractures remains controversial. This study presents a meta-analysis of fixation failures in unstable trochanteric femoral fractures using DSP devices or DSIN devices. Two independent assessors selected randomised controlled trials using a range of electronic databases, as well as reference lists of selected articles. A study quality checklist was used. The occurrence of fixation failure, in particular cut-out, was the primary subject of analysis using descriptive statistics and random-effect meta-analyses. Seventeen trials were identified. Meta-analyses showed no significant difference in the frequency of implant-related complications between the two types of devices. Iatrogenic femoral fractures associated with the use of DSIN devices represent a rare, but persistent, risk. There was a tendency for less frequent cut-out with intramedullary devices compared with DSP devices. | lld:pubmed |
pubmed-article:12734684 | pubmed:commentsCorrections | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:12734684 | pubmed:language | eng | lld:pubmed |
pubmed-article:12734684 | pubmed:journal | http://linkedlifedata.com/r... | lld:pubmed |
pubmed-article:12734684 | pubmed:citationSubset | IM | lld:pubmed |
pubmed-article:12734684 | pubmed:status | MEDLINE | lld:pubmed |
pubmed-article:12734684 | pubmed:issn | 0341-2695 | lld:pubmed |
pubmed-article:12734684 | pubmed:author | pubmed-author:HansonBB | lld:pubmed |
pubmed-article:12734684 | pubmed:author | pubmed-author:AudigéLL | lld:pubmed |
pubmed-article:12734684 | pubmed:author | pubmed-author:SwiontkowskiM... | lld:pubmed |
pubmed-article:12734684 | pubmed:issnType | Print | lld:pubmed |
pubmed-article:12734684 | pubmed:volume | 27 | lld:pubmed |
pubmed-article:12734684 | pubmed:owner | NLM | lld:pubmed |
pubmed-article:12734684 | pubmed:authorsComplete | Y | lld:pubmed |
pubmed-article:12734684 | pubmed:pagination | 197-203 | lld:pubmed |
pubmed-article:12734684 | pubmed:dateRevised | 2006-11-15 | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:meshHeading | pubmed-meshheading:12734684... | lld:pubmed |
pubmed-article:12734684 | pubmed:year | 2003 | lld:pubmed |
pubmed-article:12734684 | pubmed:articleTitle | Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices. | lld:pubmed |
pubmed-article:12734684 | pubmed:affiliation | AO Clinical Investigation and Documentation, AO ASIF Center, 7270 Davos Platz, Clavadelerstrasse, Switzerland. laurent.audige@ao-asif.ch | lld:pubmed |
pubmed-article:12734684 | pubmed:publicationType | Journal Article | lld:pubmed |
pubmed-article:12734684 | pubmed:publicationType | Comparative Study | lld:pubmed |
pubmed-article:12734684 | pubmed:publicationType | Meta-Analysis | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:12734684 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:12734684 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:12734684 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:12734684 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:12734684 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:12734684 | lld:pubmed |
http://linkedlifedata.com/r... | pubmed:referesTo | pubmed-article:12734684 | lld:pubmed |