Source:http://linkedlifedata.com/resource/pubmed/id/12734684
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
4
|
pubmed:dateCreated |
2003-8-13
|
pubmed:abstractText |
The choice between dynamic screw-intramedullary nail (DSIN) devices and dynamic screw-plate (DSP) devices for the fixation of unstable trochanteric fractures remains controversial. This study presents a meta-analysis of fixation failures in unstable trochanteric femoral fractures using DSP devices or DSIN devices. Two independent assessors selected randomised controlled trials using a range of electronic databases, as well as reference lists of selected articles. A study quality checklist was used. The occurrence of fixation failure, in particular cut-out, was the primary subject of analysis using descriptive statistics and random-effect meta-analyses. Seventeen trials were identified. Meta-analyses showed no significant difference in the frequency of implant-related complications between the two types of devices. Iatrogenic femoral fractures associated with the use of DSIN devices represent a rare, but persistent, risk. There was a tendency for less frequent cut-out with intramedullary devices compared with DSP devices.
|
pubmed:commentsCorrections | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:issn |
0341-2695
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
27
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
197-203
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:12734684-Bone Nails,
pubmed-meshheading:12734684-Bone Screws,
pubmed-meshheading:12734684-Fracture Fixation, Intramedullary,
pubmed-meshheading:12734684-Fracture Healing,
pubmed-meshheading:12734684-Hip Fractures,
pubmed-meshheading:12734684-Humans,
pubmed-meshheading:12734684-Intraoperative Complications,
pubmed-meshheading:12734684-Postoperative Complications,
pubmed-meshheading:12734684-Recovery of Function,
pubmed-meshheading:12734684-Treatment Outcome
|
pubmed:year |
2003
|
pubmed:articleTitle |
Implant-related complications in the treatment of unstable intertrochanteric fractures: meta-analysis of dynamic screw-plate versus dynamic screw-intramedullary nail devices.
|
pubmed:affiliation |
AO Clinical Investigation and Documentation, AO ASIF Center, 7270 Davos Platz, Clavadelerstrasse, Switzerland. laurent.audige@ao-asif.ch
|
pubmed:publicationType |
Journal Article,
Comparative Study,
Meta-Analysis
|