pubmed:abstractText
Reviews of stored electrograms from ICDs revealed a 5-30% incidence of short-long-short intervals preceding the onset of recurrent ventricular tachyarrhythmias. Rate stabilization by dedicated antibradycardia pacing algorithms has, therefore, been suggested to prevent onset of pause dependent tachyarrhythmias. However, the clinical efficacy of this approach has not been studied systematically. In a prospective multicenter crossover study, patients were randomized to activation or deactivation of an implemented ventricular rate stabilization algorithm (VRS) after first implant of a dual chamber ICD. After 3 months, all patients were crossed over to the alternate programming. The rate of appropriate spontaneous VA episodes was compared between VRS On and VRS Off. Stored electrograms were reviewed for evaluation of the mode of onset of tachyarrhythmias. Overall efficacy analysis was based on 309 patients enrolled in the study. Forty percent (124/309) of the patients experienced 4,973 VA episodes. Based on an intention-to-treat analysis, VRS Off and On arrhythmia incidence was 10.2 and 6.6 normalized to 3 months, respectively (risk reduction 35%; P = 0.18) On an on-treatment basis, a reduction from 9.0 episodes to 8.1 episodes (10% risk reduction, P = 0.24) was seen. In an extended Cox model adjusting for confounding variables, the relative risk for recurrent episodes was 0.92 during VRS On compared to Off (95% CI: 0.58-1.48; P = 0.74). During VRS Off, pause dependent onset was documented in only 36 (8%) of 427 visually analyzed episodes. There was no significant reduction in the incidence of recurrent ventricular tachyarrhythmias with VRS On compared to the Off programming in this prospective study.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:month
Dec
pubmed:issn
0147-8389
pubmed:author
pubmed:issnType
Print
pubmed:volume
25
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1708-14
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
2002
pubmed:articleTitle
Ventricular rate stabilization for the prevention of pause dependent ventricular tachyarrhythmias: results from a prospective study in 309 ICD recipients.
pubmed:affiliation
University Hospital Frankfurt, Germany.
pubmed:publicationType
Journal Article, Clinical Trial, Randomized Controlled Trial, Multicenter Study