pubmed:abstractText
Sapphire contact cooling is widely used to prevent non-specific epidermal injury from occurring during selective laser treatment of unwanted hair and vascular lesions. This small study was performed to examine the clinical response of the skin to 800-nm laser irradiation with varying extent of cutaneous sapphire contact cooling. Observed clinical responses are compared to those predicted by theoretical analysis in an attempt to construct a more complete picture of sapphire contact cooling and its role in preventing non-targeted tissue devitalization during laser treatment of the skin using a wavelength, pulse duration, and radiant exposure commonly used for laser hair removal.