Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
4 Suppl
pubmed:dateCreated
2002-3-5
pubmed:abstractText
Clinical trials have documented the single-agent efficacy of radioimmunotherapy (RIT) in lymphoma, and several combination therapy studies are now in progress. RIT agents are currently becoming generally available for clinical use in lymphoma therapy. Solid tumors, which are notoriously less responsive to any single agent, have demonstrated clinically useful responses, albeit temporary, and multimodality studies have been instituted. However, a sincere debate continues regarding the basic parameters to be used to define appropriate therapeutic dosing when using this modality in clinical cancer care. It is a good time to reevaluate relevant dose response information from preclinical and clinical RIT. Preclinical studies have demonstrated abundant evidence of dose response in tumor and normal tissue in homogenous model systems; however, substantive variation occurs between the dose responses of tumors with low and variable (or shed) antigen expression, as well as between histologically different tumor models. Clinical studies of various heavily pretreated patient populations given several very different RIT pharmaceuticals have led to disparate conclusions regarding patient dosing methods and dosimetric predictions of toxicity and efficacy. Single-study data on previously untreated lymphoma patients with similar histology has demonstrated a correlation of imaging dosimetry with toxicity and tumor response. High-dose therapy with bone marrow support has also demonstrated a high tumor response rate and nonmarrow normal organ toxicities that correlate with the calculated dose to those organs from imaging. In iodine-131 ((131)I)--anti-CD20 studies, (131)I was demonstrated to have variable excretion, and estimated total-body radiation dose from tracer study proved a predictive surrogate for marrow toxicity. Yttrium-90 ((90)Y)--anti-CD20, which has little (90)Y excretion from the body, demonstrated the injected dose per body weight to be more predictive of marrow toxicity than indium-111 ((111)In) tracer dosimetry methods in heavily pretreated patients, and showed maximal safety with standard mCi/kg therapy dosing. Variations in clinical RIT choices, dosing methods, and dosimetry methods emphasize the need to review the relevant information to date. Future clinical trial designs, the sophistication of dosimetry, treatment planning, and clinical treatment decisions should all be focused on achieving the best benefit-risk relationship for each patient.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
AIM
pubmed:status
MEDLINE
pubmed:month
Feb
pubmed:issn
0008-543X
pubmed:author
pubmed:copyrightInfo
Copyright 2002 American Cancer Society.
pubmed:issnType
Print
pubmed:day
15
pubmed:volume
94
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
1275-86
pubmed:dateRevised
2007-11-14
pubmed:meshHeading
pubmed:year
2002
pubmed:articleTitle
Choosing an optimal radioimmunotherapy dose for clinical response.
pubmed:affiliation
Department of Internal Medicine, Division of Hematology and Oncology, Section of Radiodiagnosis and Therapy, University of California, Davis Medical Center, Sacramento, California 95816, USA. sjdenardo@ucdavis.edu
pubmed:publicationType
Journal Article, Research Support, U.S. Gov't, P.H.S.