pubmed:abstractText |
The properties of the electron and photon beams from a 22 MeV clinical microton are presented. Favourable isodose distributions for radiation therapy are obtained for both modalities. For the electron beam this is accomplished using a dual scattering foil system in which the secondary foil is shaped to optimize uniformity and minimize energy loss and energy straggling. The photon beam is flattened by a composite filter to produce dose distributions of high uniformity over a wide depth interval.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:issn |
0348-5196
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
18
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
244-72
|
pubmed:dateRevised |
2000-12-18
|
pubmed:meshHeading | |
pubmed:year |
1979
|
pubmed:articleTitle |
Radiation beam characteristics of a 22 MeV microtron.
|
pubmed:publicationType |
Journal Article
|