pubmed:abstractText
The paper compares the results of bipolar coagulation bey means of ERBE ICC 300 diatermy coagulator and WISAP endocoagulator. The results of both types of coagulation were assessed with reference to the changes occurring on peritoneum ligamenti sacro-uterini, Douglas pouch and ovary. The best results of endometriosis foci coagulation were obtained with bipolar ball at 20-30 W; no side effects or feelings of malaise were observed in patients just after the operation or over a longer period of convalescence.