pubmed-article:11499883 | pubmed:abstractText | The performance characteristics of a method for detecting opiates (morphine, codeine, heroin, and 6-acetylmorphine [6-AM]) in oral fluid specimens were examined and compared with methods for urine specimens. The oral fluid was easily obtained using a simple device that collects between 1 and 1.5 mL of fluid for laboratory analysis. Simultaneously collected specimens from 60 known opiate abusers from a drug-treatment center were first tested using an immunoassay cutoff of 10 ng/mL in oral fluids and 2,000 ng/mL in urine. Using a second aliquot, opiate confirmation in urine was performed by gas chromatography-mass spectrometry (GC-MS) and in oral fluids by GC-MS-MS. The combined immunoassay and GC-MS-MS procedures were completed with less than 250 pL of oral fluid. Opiates identified in oral fluid specimens from heroin users included morphine, codeine, heroin, and 6-AM. The immunoassay was tested for precision, stability, and the effects of potential cross-reactants. The results yielded 93.6% agreement between oral fluid and urine, suggesting that oral fluid may be a reliable matrix for opiate detection. | lld:pubmed |