Source:http://linkedlifedata.com/resource/pubmed/id/11393473
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
5
|
pubmed:dateCreated |
2001-6-6
|
pubmed:abstractText |
The purpose of this article is to demonstrate the viability of using a high-resolution 3-D head phantom in Monte Carlo N-Particle (MCNP) for boron neutron capture therapy (BNCT) structure dosimetry. This work describes a high-resolution voxel-based model of a human head and its use for calculating absorbed doses to the structures of the brain. The Zubal head phantom is a 3-D model of a human head that can be displayed and manipulated on a computer. Several changes were made to the original head phantom which now contains over 29 critical structures of the brain and head. The modified phantom is a 85 x 109 x 120 lattice of voxels, where each voxel is 2.2 x 2.2 x 1.4 mm3. This model was translated into MCNP lattice format. As a proof of principle study, two MCNP absorbed dose calculations were made (left and right lateral irradiations) using a uniformly distributed neutron disk source with an 1/E energy spectrum. Additionally, the results of these two calculations were combined to estimate the absorbed doses from a bilateral irradiation. Radiobiologically equivalent (RBE) doses were calculated for all structures and were normalized to 12.8 Gy-Eq. For a left lateral irradiation, the left motor cortex receives the limiting RBE dose. For a bilateral irradiation, the insula cortices receive the limiting dose. Among the nonencephalic structures, the parotid glands receive RBE doses that were within 15% of the limiting dose.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
0094-2405
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
28
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
780-6
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:11393473-Boron Neutron Capture Therapy,
pubmed-meshheading:11393473-Brain,
pubmed-meshheading:11393473-Head,
pubmed-meshheading:11393473-Humans,
pubmed-meshheading:11393473-Monte Carlo Method,
pubmed-meshheading:11393473-Phantoms, Imaging,
pubmed-meshheading:11393473-Radiometry,
pubmed-meshheading:11393473-Software,
pubmed-meshheading:11393473-Tissue Distribution
|
pubmed:year |
2001
|
pubmed:articleTitle |
Absorbed dose estimates to structures of the brain and head using a high-resolution voxel-based head phantom.
|
pubmed:affiliation |
Department of Mechanical Engineering, The Ohio State University, Columbus 43210, USA.
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, Non-P.H.S.,
Research Support, Non-U.S. Gov't
|