Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
3
pubmed:dateCreated
2001-6-6
pubmed:abstractText
A highly sensitive method for the determination of D-lactic acid and 3-hydroxybutyric acid (3-HB) in rat plasma was developed using high-performance liquid chromatography with octadecylsilica (ODS) connected to a chiral column. At first, (D + L)-lactic acid and 3-HB in the plasma were derivatized with a fluorescent reagent, 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ), separated on the ODS column and determined fluorimetrically at 547 nm with 491 nm of excitation wavelength. During the separation step on the ODS, the peak fraction of (D + L)-lactate derivative was introduced directly to a phenylcarbamoylated beta-cyclodextrin chiral column by changing the flow of the eluent via a six-port valve. Then, D-lactate derivative was separated enantiomerically from the L-lactate derivative, and the enantiomeric ratio was determined from the chromatogram. Intra- and inter-day accuracy values for the determination of D-lactic acid in 10 microL of rat plasma were 97.8-109.2 and 98.4-109.9%, and those for 3-HB were 99.8-108.4 and 99.8-103.8%, respectively. The intra- and inter-day precision values were within 4.6 and 5.1% for D-lactic acid, and 2.7 and 2.4% for 3-HB, respectively. The detection limits for D-lactic acid and 3-HB were approximately 2.0 and 0.04 microM, respectively (signal-to-noise ratio 3). The proposed method was applied to the plasma of diabetic rats induced by intraperitoneal administration of streptozotocin, and the significant increases of both D-lactic acid and 3-HB concentrations were observed in the diabetic rats as compared to the normal rats.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
May
pubmed:issn
0269-3879
pubmed:author
pubmed:copyrightInfo
Copyright 2001 John Wiley & Sons, Ltd.
pubmed:issnType
Print
pubmed:volume
15
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
189-95
pubmed:dateRevised
2003-11-14
pubmed:meshHeading
pubmed:year
2001
pubmed:articleTitle
Simultaneous determination of D-lactic acid and 3-hydroxybutyric acid in rat plasma using a column-switching HPLC with fluorescent derivatization with 4-nitro-7-piperazino-2,1,3-benzoxadiazole (NBD-PZ).
pubmed:affiliation
Department of Bio-Analytical Chemistry, Graduate School of Pharmaceutical Sciences, The University of Tokyo, Hongo, Bunkyo-ku, Tokyo, 113-0033 Japan.
pubmed:publicationType
Journal Article