pubmed:dateCreated |
2001-5-8
|
pubmed:abstractText |
A simple and novel technique that utilizes the zero-crossing points of the first time derivative of intra-ventricular pressure (dP/dt) to mark systole, is proposed. Discrete differentiation of the sampled pressure waveform is calculated using a difference equation. Filtration of high-frequency noise in dP/dt is achieved using a low-pass Butterworth filter of order 4 and a cutoff frequency of 10 Hz. The filter is realized digitally using infinite impulse response filter stages. Double filtering of discrete dP/dt is used to eliminate time shifts. The methods are evaluated on data obtained from six large, white, anaesthetised and open chest pigs, instrumented with a conductance catheter. The zero-crossing points of the filtered dP/dt compare very well with the R-waves of the electrocardiogram (ECG) as markers of systole. The mean error is 1.3% of the duration of the heartcycle. Significantly, our results provide a solution to a problem often encountered with multiuse pressure-volume catheters when an ECG signal cannot be obtained. In this situation, the zero-crossing points of dP/dt, rather than the R-waves of the ECG, can be used as a marker of systole, thus enabling the construction of end-systolic pressure-volume relations to assess cardiac contractility.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
0018-9294
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
48
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
606-10
|
pubmed:dateRevised |
2009-11-11
|
pubmed:meshHeading |
pubmed-meshheading:11341537-Animals,
pubmed-meshheading:11341537-Calibration,
pubmed-meshheading:11341537-Electrocardiography,
pubmed-meshheading:11341537-Female,
pubmed-meshheading:11341537-Male,
pubmed-meshheading:11341537-Signal Processing, Computer-Assisted,
pubmed-meshheading:11341537-Swine,
pubmed-meshheading:11341537-Systole,
pubmed-meshheading:11341537-Ventricular Function, Left
|
pubmed:year |
2001
|
pubmed:articleTitle |
A novel and simple technique to allow detection of the position of the R-waves from intraventricular pressure waveforms: application to the conductance catheter method.
|
pubmed:affiliation |
Department of Physiology, The Medical School, The University of Birmingham, Edgbaston, UK. a.h.al-khalidi@bham.ac.uk
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|