Source:http://linkedlifedata.com/resource/pubmed/id/11241714
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
3
|
pubmed:dateCreated |
2001-3-12
|
pubmed:abstractText |
A new phase-shifted EPI pulse sequence is described that encodes EPI phase errors due to all off-resonance factors, including B(o) field inhomogeneity, eddy current effects, and gradient waveform imperfections. Combined with the previously proposed multichannel modulation postprocessing algorithm (Chen and Wyrwicz, MRM 1999;41:1206-1213), the encoded phase error information can be used to effectively remove geometric distortions in subsequent EPI scans. The proposed EPI distortion correction technique has been shown to be effective in removing distortions due to gradient waveform imperfections and phase gradient-induced eddy current effects. In addition, this new method retains advantages of the earlier method, such as simultaneous correction of different off-resonance factors without use of a complicated phase unwrapping procedure. The effectiveness of this technique is illustrated with EPI studies on phantoms and animal subjects. Implementation to different versions of EPI sequences is also described. Magn Reson Med 45:525-528, 2001.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0740-3194
|
pubmed:author | |
pubmed:copyrightInfo |
Copyright 2001 Wiley-Liss, Inc.
|
pubmed:issnType |
Print
|
pubmed:volume |
45
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
525-8
|
pubmed:dateRevised |
2007-11-14
|
pubmed:meshHeading |
pubmed-meshheading:11241714-Animals,
pubmed-meshheading:11241714-Artifacts,
pubmed-meshheading:11241714-Brain,
pubmed-meshheading:11241714-Echo-Planar Imaging,
pubmed-meshheading:11241714-Humans,
pubmed-meshheading:11241714-Image Enhancement,
pubmed-meshheading:11241714-Image Processing, Computer-Assisted,
pubmed-meshheading:11241714-Imaging, Three-Dimensional,
pubmed-meshheading:11241714-Phantoms, Imaging,
pubmed-meshheading:11241714-Rabbits,
pubmed-meshheading:11241714-Sensitivity and Specificity
|
pubmed:year |
2001
|
pubmed:articleTitle |
Optimized distortion correction technique for echo planar imaging.
|
pubmed:affiliation |
Center for MR Research, ENH Research Institute, Northwestern University, Evanston, Illinois 60201, USA.
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, P.H.S.
|