pubmed:abstractText |
Water samples and pipe coupons were collected from the Brussel's drinking water distribution system (DS). A treated surface water and various groundwaters feed this DS. Parameters related to bacterial regrowth have been measured on these samples: temperature, concentrations of free residual chlorine, concentration of biodegradable dissolved organic carbon (BDOC), abundance of suspended bacteria, densities of fixed bacteria and levels of bacterial activity. Results showed that groundwaters were less susceptible to favor bacterial regrowth in the DS pipes. Treated surface water and mixed waters had the highest potential of bacterial regrowth in the DS dead ends. Results also showed that the potential regrowth induced by the distribution of a treated surface water could be reduced if: (1) the BDOC levels were below 0.25 mg C/l at the outlet of the surface water treatment plant; (2) a significant free chlorine residual was present within the whole DS. Second-stage biological filtration using granular activated carbon is now under construction at the surface water treatment plant feeding a part of this DS. This treatment implementation should reduce BDOC levels and chlorine demand of the treated surface water and will further reduce the slight regrowth phenomena observed in this DS.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0043-1354
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
35
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
675-82
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:11228964-Belgium,
pubmed-meshheading:11228964-Biomass,
pubmed-meshheading:11228964-Chlorine,
pubmed-meshheading:11228964-Filtration,
pubmed-meshheading:11228964-Surface Properties,
pubmed-meshheading:11228964-Temperature,
pubmed-meshheading:11228964-Waste Management,
pubmed-meshheading:11228964-Water Microbiology,
pubmed-meshheading:11228964-Water Purification,
pubmed-meshheading:11228964-Water Supply
|
pubmed:year |
2001
|
pubmed:articleTitle |
Bacterial dynamics in the drinking water distribution system of Brussels.
|
pubmed:affiliation |
Ecologie des Systèmes Aquatiques, Université Libre de Bruxelles, Campus de la Plaine, CP 221, B-1050 Brussels, Belgium. patrick.niquette@sympatico.ca
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|