Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
5-6
pubmed:dateCreated
2001-2-9
pubmed:abstractText
At present, no standard manufacturing guideline exists for depositing hydroxyapatite (HA) on implant surfaces. Although animal and in vitro studies have reported on the benefits of using HA-coated implants as well as the risks of dissolution, these short-term studies did not demonstrate that the dissolution of the HA coating leads to a loss of implants. In addition, many in vivo and clinical studies did not include the chemical and structural characterization of the coatings, and thus comparisons between studies are difficult. In the clinics, the recommendation is that HA-coated screw implants be used for the anterior maxilla and posterior mandible where the bone depth exceeds 10 mm and when the cortical layer is thinner and spongiosia is less dense. In the posterior maxilla or when the cortical layer is very thin with low density, the use of HA-coated cylindrical implants is recommended. However, there are concerns for using HA-coated implants. The clinician needs to take into consideration the enhanced bacterial susceptibility of HA coatings compared with titanium implants. In addition, the clinician needs to consider the possible failure of HA coatings as a result of coating-substrate interfacial fracture. Finally, besides the surgical skills, it is also important that the clinical investigators be well versed with the materials characterization needed for HA-coated implants, the problems associated with the current HA coatings, and the indications for use. In addition, the correlation between well characterized coatings and their effect on bone formation rate and long-term implant success, coating-implant interfacial strength, and alternative superior coating process need to be investigated further.
pubmed:grant
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:issn
0278-940X
pubmed:author
pubmed:issnType
Print
pubmed:volume
28
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
667-707
pubmed:dateRevised
2008-11-21
pubmed:meshHeading
pubmed:year
2000
pubmed:articleTitle
Hydroxyapatite and their use as coatings in dental implants: a review.
pubmed:affiliation
The University of Texas Health Science Center at San Antonio, Department of Restorative Dentistry, 78229-3900, USA. ong@uthscsa.edu
pubmed:publicationType
Journal Article, In Vitro, Research Support, U.S. Gov't, P.H.S., Review, Research Support, Non-U.S. Gov't