2000-9-25
|
pubmed:abstractText |
UCN-01, 7-hydroxystaurosporine, is an antagonist of protein kinase C, as well as causing cell cycle arrest. We developed and validated an HPLC assay method for the quantitation of UCN-01. Plasma and saliva standard curves were prepared at concentrations ranging from 0.2 to 20.0 microgram/mL and 4.0 to 200.0 ng/mL, respectively. The sample preparation consisted of acetonitrile precipitation. Separation was accomplished on a phenyl column and a C-18 precolumn insert utilizing a gradient-profile consisting of ammonium acetate and acetonitrile. UV detection was set at 295 nm for UCN-01 and 323 nm for umbelliferone, the internal standard. For fluorescence detection, excitation occurred at 290 nm, while emission was at 400 nm. The retention times were around 4 min for umbelliferone and 9.1 for UCN-01. Inter- and intra-assay errors of accuracy were less than 7. 0% and 10.7%, respectively, for the plasma standard curve and less than 7.1% and 6.7%, respectively, for the saliva standard curve. The recoveries of UCN-01 and umbelliferone from saliva were 81.4 +/- 0. 9% and 106.3 +/- 10.2%, respectively. The recovery of UCN-01 from plasma was 97.9 +/- 7.1% and for umbelliferone was 103.3 +/- 2.3%. This method is suitable for quantifying UCN-01 in patient samples and further characterizing the clinical pharmacology of this compound. Published in 2000 by John Wiley & Sons, Ltd.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical |
http://linkedlifedata.com/resource/pubmed/chemical/7-hydroxystaurosporine,
http://linkedlifedata.com/resource/pubmed/chemical/Alkaloids,
http://linkedlifedata.com/resource/pubmed/chemical/Enzyme Inhibitors,
http://linkedlifedata.com/resource/pubmed/chemical/Protein Kinase C,
http://linkedlifedata.com/resource/pubmed/chemical/Staurosporine
|
pubmed:status |
MEDLINE
|
pubmed:month |
Aug
|
pubmed:issn |
0269-3879
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
14
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
338-43
|
pubmed:dateRevised |
2007-11-15
|
pubmed:meshHeading |
pubmed-meshheading:10960835-Alkaloids,
pubmed-meshheading:10960835-Calibration,
pubmed-meshheading:10960835-Chromatography, High Pressure Liquid,
pubmed-meshheading:10960835-Enzyme Inhibitors,
pubmed-meshheading:10960835-Humans,
pubmed-meshheading:10960835-Protein Kinase C,
pubmed-meshheading:10960835-Reproducibility of Results,
pubmed-meshheading:10960835-Saliva,
pubmed-meshheading:10960835-Spectrometry, Fluorescence,
pubmed-meshheading:10960835-Spectrophotometry, Ultraviolet,
pubmed-meshheading:10960835-Staurosporine
|
pubmed:year |
2000
|
pubmed:articleTitle |
A high-performance liquid chromatography method using ultraviolet and fluorescence detection for the quantitation of UCN-01, 7-hydroxystaurosporine, from human plasma and saliva.
|
pubmed:affiliation |
Medicine Branch, Division of Clinical Sciences, National Cancer Institute, National Institutes of Health, Bethesda, MD 20892, USA.
|
pubmed:publicationType |
Journal Article
|