Source:http://linkedlifedata.com/resource/pubmed/id/10870719
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
6
|
pubmed:dateCreated |
2000-10-19
|
pubmed:abstractText |
A method for compliance estimation employing magnetic resonance pulse wave velocity measurement is presented. Time-resolved flow waves are recorded at several positions along the vessel using a phase contrast sequence, and pulse wave velocity is calculated from the delay of the wave onsets. Using retrospective cardiac gating in combination with an optically decoupled electrocardiogram acquisition, a high temporal resolution of 3 ms can be achieved. A phantom set-up for the simulation of pulsatile flow in a compliant vessel is described. In the phantom, relative errors of pulse wave velocity estimation were found to be about 15%, whereas in a volunteer, larger errors were found that might be caused by vessel branches. Results of pulse wave velocity estimation agree with direct aortic distension measurements which rely on a peripheral estimate of aortic pressure and are therefore less accurate. Studies in 12 volunteers show values of pulse wave velocity consistent with the literature; in particular the well-known increase in pulse wave velocity with age was observed. Preliminary results show that the method can be applied to aortic aneurysms.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jun
|
pubmed:issn |
0031-9155
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
45
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
1703-13
|
pubmed:dateRevised |
2006-11-15
|
pubmed:meshHeading |
pubmed-meshheading:10870719-Adult,
pubmed-meshheading:10870719-Age Factors,
pubmed-meshheading:10870719-Aged,
pubmed-meshheading:10870719-Aorta,
pubmed-meshheading:10870719-Aorta, Abdominal,
pubmed-meshheading:10870719-Aortic Aneurysm,
pubmed-meshheading:10870719-Electrocardiography,
pubmed-meshheading:10870719-Humans,
pubmed-meshheading:10870719-Magnetic Resonance Spectroscopy,
pubmed-meshheading:10870719-Middle Aged,
pubmed-meshheading:10870719-Models, Statistical,
pubmed-meshheading:10870719-Phantoms, Imaging,
pubmed-meshheading:10870719-Risk Factors,
pubmed-meshheading:10870719-Time Factors
|
pubmed:year |
2000
|
pubmed:articleTitle |
Estimation of aortic compliance using magnetic resonance pulse wave velocity measurement.
|
pubmed:affiliation |
Deutsches Krebsforschungszentrum, Radiologische Diagnostik und Therapie, Heidelberg, Germany.
|
pubmed:publicationType |
Journal Article,
Research Support, Non-U.S. Gov't
|