pubmed:abstractText |
PURPOSE AND OBJECTIVE: The primary goal of this study was to examine systematically the dosimetric effect of small patient movements and linear accelerator angular setting misalignments in the delivery of intensity modulated radiation therapy. We will also provide a method for estimating dosimetric errors for an arbitrary combination of these uncertainties.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
Jul
|
pubmed:issn |
0167-8140
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
56
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
97-108
|
pubmed:dateRevised |
2011-1-11
|
pubmed:meshHeading |
pubmed-meshheading:10869760-Humans,
pubmed-meshheading:10869760-Immobilization,
pubmed-meshheading:10869760-Lumbar Vertebrae,
pubmed-meshheading:10869760-Movement,
pubmed-meshheading:10869760-Nasopharyngeal Neoplasms,
pubmed-meshheading:10869760-Quality Control,
pubmed-meshheading:10869760-Radiation Dosage,
pubmed-meshheading:10869760-Radiotherapy Dosage,
pubmed-meshheading:10869760-Radiotherapy Planning, Computer-Assisted,
pubmed-meshheading:10869760-Spinal Neoplasms
|
pubmed:year |
2000
|
pubmed:articleTitle |
Dosimetric effects of patient displacement and collimator and gantry angle misalignment on intensity modulated radiation therapy.
|
pubmed:affiliation |
Department of Radiation Oncology, Stanford University School of Medicine, 300 Pasteur Drive, Stanford, CA 94305, USA.
|