Source:http://linkedlifedata.com/resource/pubmed/id/10867249
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
2000-8-11
|
pubmed:abstractText |
To optimize the benefits of transdermal iontophoresis, it is necessary to develop a suitable animal model that would allow for extensive assessments of the biological effects associated with electro-transport. Rabbit skin responses to iontophoresis treatments were evaluated by visual scoring and by non-invasive bioengineering parameters and compared with available human data. In the current density range 0.1-1.0 mA/cm(2) applied for 1 h using 0.9% w/v NaCl and 0.5 mA/cm(2) for up to 4 h, no significant irritation was observed. 2 mA/cm(2) applied through an area of 1 cm(2) for 1 h resulted in slight erythema at both active electrode sites but without significant changes in transepidermal water loss (TEWL) and laser Doppler velocimetry (LDV). A value of 4 mA/cm(2) under similar conditions caused moderate erythema at the anode and cathode with TEWL and LDV being significantly elevated at both sites; 1 mA/cm(2) current applied for 4 h, caused moderate erythema at both anode and cathode; and 1 mA/cm(2) applied for 1 h caused no irritation when the area of exposure was increased from 1 to 4.5 cm(2). When significant irritation and barrier impairment occurred, the erythema was resolved within 24 h with barrier recovery complete 3-5 days post-treatment. Rabbit skin thus shows promise as an acceptable model for iontophoresis experiments.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:status |
MEDLINE
|
pubmed:month |
May
|
pubmed:issn |
0378-5173
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
10
|
pubmed:volume |
200
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
195-206
|
pubmed:dateRevised |
2008-11-21
|
pubmed:meshHeading |
pubmed-meshheading:10867249-Administration, Cutaneous,
pubmed-meshheading:10867249-Animals,
pubmed-meshheading:10867249-Electric Conductivity,
pubmed-meshheading:10867249-Electric Impedance,
pubmed-meshheading:10867249-Galvanic Skin Response,
pubmed-meshheading:10867249-Humans,
pubmed-meshheading:10867249-Iontophoresis,
pubmed-meshheading:10867249-Rabbits,
pubmed-meshheading:10867249-Skin,
pubmed-meshheading:10867249-Skin Physiological Phenomena
|
pubmed:year |
2000
|
pubmed:articleTitle |
An in vivo investigation of the rabbit skin responses to transdermal iontophoresis.
|