Statements in which the resource exists.
SubjectPredicateObjectContext
pubmed-article:10609996rdf:typepubmed:Citationlld:pubmed
pubmed-article:10609996lifeskim:mentionsumls-concept:C0025663lld:lifeskim
pubmed-article:10609996lifeskim:mentionsumls-concept:C1557561lld:lifeskim
pubmed-article:10609996lifeskim:mentionsumls-concept:C0681829lld:lifeskim
pubmed-article:10609996lifeskim:mentionsumls-concept:C1283195lld:lifeskim
pubmed-article:10609996pubmed:issue10lld:pubmed
pubmed-article:10609996pubmed:dateCreated2000-1-7lld:pubmed
pubmed-article:10609996pubmed:abstractTextThis paper describes and tests the LL-EPI method for obtaining quantitative T1 estimates in a few seconds thereby allowing dynamic T1 studies. It is shown that the method works even when there is an inflow into the imaged volume, e.g., in a vessel. No calibration is needed. The method has been tested in a phantom study with several different scan parameter set-ups, with and without inflow. The method shows robustness and individual scan parameters and inflow rates do not influence the ability to calculate the Gd-DTPA concentration. Linearity prevail between the measured 1/T1 and the Gd-DTPA concentration in the range 150 < T1 < 2500 ms. In a dynamic Gd-DTPA phantom study, it was shown that the dynamic LL-EPI T1 mapping technique was three times more sensitive than the signal from a T2*-weighted EPI sequence. In an in vivo study, dynamic T1 mapping of the Gd-DTPA uptake in a meningioma was performed. Inspection of the uptake curves indicates that the method is feasible in clinical perfusion studies.lld:pubmed
pubmed-article:10609996pubmed:languageenglld:pubmed
pubmed-article:10609996pubmed:journalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:10609996pubmed:citationSubsetIMlld:pubmed
pubmed-article:10609996pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:10609996pubmed:chemicalhttp://linkedlifedata.com/r...lld:pubmed
pubmed-article:10609996pubmed:statusMEDLINElld:pubmed
pubmed-article:10609996pubmed:monthDeclld:pubmed
pubmed-article:10609996pubmed:issn0730-725Xlld:pubmed
pubmed-article:10609996pubmed:authorpubmed-author:KarlssonMMlld:pubmed
pubmed-article:10609996pubmed:authorpubmed-author:NordellBBlld:pubmed
pubmed-article:10609996pubmed:issnTypePrintlld:pubmed
pubmed-article:10609996pubmed:volume17lld:pubmed
pubmed-article:10609996pubmed:ownerNLMlld:pubmed
pubmed-article:10609996pubmed:authorsCompleteYlld:pubmed
pubmed-article:10609996pubmed:pagination1481-8lld:pubmed
pubmed-article:10609996pubmed:dateRevised2006-11-15lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:meshHeadingpubmed-meshheading:10609996...lld:pubmed
pubmed-article:10609996pubmed:year1999lld:pubmed
pubmed-article:10609996pubmed:articleTitlePhantom and in vivo study of the Look-Locher T1 mapping method.lld:pubmed
pubmed-article:10609996pubmed:affiliationMR Research Center, Karolinska Institute, Stockholm, Sweden. magnus@mrc.ks.selld:pubmed
pubmed-article:10609996pubmed:publicationTypeJournal Articlelld:pubmed
pubmed-article:10609996pubmed:publicationTypeComparative Studylld:pubmed
pubmed-article:10609996pubmed:publicationTypeResearch Support, Non-U.S. Gov'tlld:pubmed