Source:http://linkedlifedata.com/resource/pubmed/id/10601193
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
6
|
pubmed:dateCreated |
2000-2-3
|
pubmed:abstractText |
The aim of the study was to validate a nonradioactive method for relative blood flow measurements in severely injured lungs that avoids labor-intensive tissue processing. The use of fluorescent-labeled microspheres was compared with the standard radiolabeled-microsphere method. In seven sheep, lung injury was established by using oleic acid. Five pairs of radio- and fluorescent-labeled microspheres were injected before and after established lung injury. Across all animals, 175 pieces were selected randomly. The radioactivity of each piece was determined by using a scintillation counter. The fluorescent dye was extracted from each piece with a solvent without digestion or filtering. The fluorescence was determined with an automated fluorescent spectrophotometer. Perfusion was calculated for each piece from both the radioactivity and fluorescence and volume normalized. Correlations between flow determined by the two methods were in the range from 0.987 +/- 0.007 (SD) to 0.991 +/- 0.002 (SD) after 9 days of soaking. Thus the fluorescent microsphere technique is a valuable tool for investigating regional perfusion in severely injured lungs and can replace radioactivity.
|
pubmed:grant | |
pubmed:keyword | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Dec
|
pubmed:issn |
8750-7587
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:volume |
87
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
2381-5
|
pubmed:dateRevised |
2007-11-14
|
pubmed:meshHeading |
pubmed-meshheading:10601193-Acute Disease,
pubmed-meshheading:10601193-Animals,
pubmed-meshheading:10601193-Female,
pubmed-meshheading:10601193-Humans,
pubmed-meshheading:10601193-Infant, Newborn,
pubmed-meshheading:10601193-Male,
pubmed-meshheading:10601193-Microspheres,
pubmed-meshheading:10601193-Pulmonary Circulation,
pubmed-meshheading:10601193-Radioisotopes,
pubmed-meshheading:10601193-Respiratory Distress Syndrome, Adult,
pubmed-meshheading:10601193-Sheep
|
pubmed:year |
1999
|
pubmed:articleTitle |
Validation of fluorescent-labeled microspheres for measurement of relative blood flow in severely injured lungs.
|
pubmed:affiliation |
Department of Anesthesiology and Intensive Care, Carl Gustav Carus University Hospital, 01307 Dresden, Germany.
|
pubmed:publicationType |
Journal Article,
Research Support, U.S. Gov't, P.H.S.,
Research Support, Non-U.S. Gov't
|