pubmed:abstractText
Buildings are often insulated with sprayed-in-place polyurethane foam in spite of the fact that few studies have been carried out on exposure levels to isocyanates during the spraying process. This paper is meant to provide new data on personal exposure to methylene-bis (4-phenylisocyanate) (MDI) while dwellings and office buildings are being insulated with polyurethane foam. An impinger using a 1-(2-methoxyphenyl)piperazine toluene solution as absorbent was used to take personal samples for the sprayer and helper during indoor and outdoor applications. The analytical results show that the levels of exposure were significant, especially for the sprayer, with values of up to 0.077 mg m-3 and 0.400 mg m-3 during outdoor and indoor applications, respectively. The helper's exposure was always lower.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:chemical
pubmed:status
MEDLINE
pubmed:month
Aug
pubmed:issn
0003-4878
pubmed:author
pubmed:issnType
Print
pubmed:volume
43
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
415-9
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1999
pubmed:articleTitle
Exposure to MDI during the process of insulating buildings with sprayed polyurethane foam.
pubmed:affiliation
Centro de Seguridad e Higiene en el Trabajo, Sevilla, Spain.
pubmed:publicationType