Statements in which the resource exists as a subject.
PredicateObject
rdf:type
lifeskim:mentions
pubmed:issue
5
pubmed:dateCreated
1999-7-30
pubmed:abstractText
The Amplatz Thrombectomy Device (ATD) is a percutaneous, rotational thrombectomy catheter, capable of recirculating and homogenizing the thrombus in order to obtain mechanical clot dissolution. The authors present their experience with mechanical thrombectomy with the ATD in eight cases of ilio-caval thrombosis. Under temporary caval filter protection, the ATD was introduced through the right transjugular approach (in one patient this was used in combination with the right femoral approach) and activated for a time ranging from 90 to 180 s. Complete clearing of thrombotic material in the treated venous segments was achieved in six cases (75 %), partial success was obtained in one case (12.5 %) and failure occurred in one patient (12.5 %). One patient developed a recurrence of venous iliac thrombosis 1 week after the procedure and postphlebitic syndrome 6 months after the first episode of deep venous thrombosis, and one patient died from acute myocardial infarction, unrelated to thrombectomy session, after 3 days. A negative clinical and radiological follow-up at 3, 6, 12 and 24 months was obtained in the remaining six patients. If a fresh free-floating ilio-caval clot must be removed immediately, the ATD can be effective under temporary filter protection.
pubmed:language
eng
pubmed:journal
pubmed:citationSubset
IM
pubmed:status
MEDLINE
pubmed:issn
0938-7994
pubmed:author
pubmed:issnType
Print
pubmed:volume
9
pubmed:owner
NLM
pubmed:authorsComplete
Y
pubmed:pagination
951-8
pubmed:dateRevised
2004-11-17
pubmed:meshHeading
pubmed:year
1999
pubmed:articleTitle
Percutaneous ilio-caval thrombectomy with the Amplatz device: preliminary results.
pubmed:affiliation
Department of Radiology, "Tor Vergata" University of Rome, S. Eugenio Hospital, P.le Umanesimo 10, I-00144 Rome, Italy.
pubmed:publicationType
Journal Article