Source:http://linkedlifedata.com/resource/pubmed/id/10089171
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
1999-7-14
|
pubmed:abstractText |
There has been a need for development of microwave resonator designs optimized to provide high sensitivity and high stability for EPR spectroscopy and imaging measurements of in vivo systems. The design and construction of a novel reentrant resonator with transversely oriented electric field (TERR) and rectangular sample opening cross section for EPR spectroscopy and imaging of in vivo biological samples, such as the whole body of mice and rats, is described. This design with its transversely oriented capacitive element enables wide and simple setting of the center frequency by trimming the dimensions of the capacitive plate over the range 100-900 MHz with unloaded Q values of approximately 1100 at 750 MHz, while the mechanical adjustment mechanism allows smooth continuous frequency tuning in the range +/-50 MHz. This orientation of the capacitive element limits the electric field based loss of resonator Q observed with large lossy samples, and it facilitates the use of capacitive coupling. Both microwave performance data and EPR measurements of aqueous samples demonstrate high sensitivity and stability of the design, which make it well suited for in vivo applications.
|
pubmed:grant | |
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Apr
|
pubmed:issn |
1090-7807
|
pubmed:author | |
pubmed:copyrightInfo |
Copyright 1999 Academic Press.
|
pubmed:issnType |
Print
|
pubmed:volume |
137
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
373-8
|
pubmed:dateRevised |
2011-8-1
|
pubmed:meshHeading |
pubmed-meshheading:10089171-Animals,
pubmed-meshheading:10089171-Diagnostic Imaging,
pubmed-meshheading:10089171-Electromagnetic Fields,
pubmed-meshheading:10089171-Electron Spin Resonance Spectroscopy,
pubmed-meshheading:10089171-Free Radicals,
pubmed-meshheading:10089171-Mice,
pubmed-meshheading:10089171-Microwaves,
pubmed-meshheading:10089171-Rats,
pubmed-meshheading:10089171-Spin Trapping
|
pubmed:year |
1999
|
pubmed:articleTitle |
A tunable reentrant resonator with transverse orientation of electric field for in vivo EPR spectroscopy.
|
pubmed:affiliation |
Department of Medicine, Division of Cardiology and the EPR Center, Johns Hopkins Medical Institutions, 5501 Hopkins Bayview Circle, Baltimore, Maryland 21224, USA.
|
pubmed:publicationType |
Journal Article
|