Source:http://linkedlifedata.com/resource/pubmed/id/10089100
Switch to
Predicate | Object |
---|---|
rdf:type | |
lifeskim:mentions | |
pubmed:issue |
2
|
pubmed:dateCreated |
1999-4-7
|
pubmed:abstractText |
The influence of antibody valency in a displacement immunoassay was investigated by comparing the whole antibody molecule with the corresponding Fab-fragment. The displacement immunoassay for the herbicide 2,4-dichlorophenoxyacetic acid (2,4-D) takes advantage of the cross-reactivity of monoclonal anti-2,4-D antibodies and the Fab-fragments toward immobilized 2-methyl-4-chlorophenoxyacetic acid (MCPA). Due to the low affinity of the antibodies toward MCPA (cross-reactivity of approximately 30%), the addition of 2,4-D resulted in a displacement of the antibodies or the fragments. The detection limits obtained with whole anti-2,4-D antibodies and Fab-fragments were 0.1 microg/l and 0.01 microg/l 2,4-D, respectively. The whole antibodies and the Fab-fragments show similarities, such as the cross-reactivity toward MCPA (26% and 33%), and some characteristics of the calibration curve, for example the large detection range and the sensitivity. In contrast to the bivalent antibodies, however, increasing the hapten/protein ratios of the immobilized MCPA-BSA conjugates did not affect the detection limit when using the Fab-fragments. Moreover, kinetic experiments reveal a faster displacement reaction with the Fab-fragments. A disadvantage of using the Fab-fragments is the generation of lower absorbance values in the ELISA.
|
pubmed:language |
eng
|
pubmed:journal | |
pubmed:citationSubset |
IM
|
pubmed:chemical | |
pubmed:status |
MEDLINE
|
pubmed:month |
Mar
|
pubmed:issn |
0022-1759
|
pubmed:author | |
pubmed:issnType |
Print
|
pubmed:day |
4
|
pubmed:volume |
223
|
pubmed:owner |
NLM
|
pubmed:authorsComplete |
Y
|
pubmed:pagination |
217-26
|
pubmed:dateRevised |
2005-11-17
|
pubmed:meshHeading |
pubmed-meshheading:10089100-2,4-Dichlorophenoxyacetic Acid,
pubmed-meshheading:10089100-Antibodies,
pubmed-meshheading:10089100-Antibody Affinity,
pubmed-meshheading:10089100-Binding, Competitive,
pubmed-meshheading:10089100-Calibration,
pubmed-meshheading:10089100-Cross Reactions,
pubmed-meshheading:10089100-Haptens,
pubmed-meshheading:10089100-Immunoassay,
pubmed-meshheading:10089100-Immunoglobulin Fab Fragments,
pubmed-meshheading:10089100-Kinetics
|
pubmed:year |
1999
|
pubmed:articleTitle |
Influence of antibody valency in a displacement immunoassay for the quantitation of 2,4-dichlorophenoxyacetic acid.
|
pubmed:affiliation |
Institut für Chemo- und Biosensorik, Münster, Germany.
|
pubmed:publicationType |
Journal Article
|